RT Journal Article SR Electronic T1 UV light dosage distribution over irregular respirator surfaces. Methods and implications for safety JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2020.04.07.20057224 DO 10.1101/2020.04.07.20057224 A1 Baluja, Aurora A1 Arines, Justo A1 Vilanova, Ramón A1 Cortiñas, Julio A1 Bao, Carmen A1 Flores, Maite YR 2020 UL http://medrxiv.org/content/early/2020/08/07/2020.04.07.20057224.abstract AB Background and Objectives The SARS-CoV-2 pandemic has led to a global decrease in personal protective equipment (PPE), especially filtering facepiece respirators (FFRs). Ultraviolet-C wavelength is a promising way of decontamination, however adequate dosimetry is needed to ensure balance between over and underexposed areas and provide reliable results. Our study demonstrates that UVGI light irradiance varies significantly on different respirator angles and propose a method to decontaminate several masks at once ensuring appropriate dosage in shaded zones.Methods An UVGI irradiator was built with internal dimensions of 69.5 × 55 × 33 cm with three 15W UV lamps. Inside, a grating of 58 × 41 × 15 cm was placed to hold the masks. Two different flat fold respirator models were used to assess irradiance, four of model Aura 9322 3M of dimensions 17 × 9 × 4cm (tri-fold), and two of model SAFE 231FFP3NR (bi-fold) with dimensions 17 × 6 × 5 cm. A spectrometer STN-SilverNova was employed to verify wavelength spectrum and surface irradiance. A simulation was performed to find the irradiance pattern inside the box and the six masks placed inside. These simulations were carried out using the software DIALUX EVO 8.2.Results The data obtained reveal that the irradiance received inside the manufactured UVGI-irradiator depends not only on the distance between the lamps plane and the base of the respirators but also on the orientation and shape of the masks. This point becomes relevant in order to assure that all the respirators inside the chamber receive the correct dosage.Conclusion Irradiance over FFR surfaces depend on several factors such as distance and angle of incidence of the light source. Careful irradiance measurement and simulation can ensure reliable dosage in the whole mask surface, balancing overexposure. Closed box systems might provide a more reliable, reproducible UVGI dosage than open settings.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis work was partially supported by the Conselleria de Educacion Program for Development of a Strategic Grouping in Materials - AeMAT Grant No. ED431E2018/08 and Xunta de Galicia ref. ED431B2017/64.Author DeclarationsAll relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.YesAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAvailable data are included in the manuscript