RT Journal Article SR Electronic T1 Non-invasive Temporal Interference Stimulation of the Hippocampus Suppresses Epileptic Biomarkers in Patients with Epilepsy: Biophysical Differences between Kilohertz and Amplitude Modulated Stimulation JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2024.12.05.24303799 DO 10.1101/2024.12.05.24303799 A1 Acerbo, Emma A1 Missey, Florian A1 Dickey, Adam S. A1 Trajlinek, Jan A1 Studnička, Ondřej A1 Lubrano, Claudia A1 de Araújo e Silva, Mariane A1 Brady, Evan A1 Všianský, Vit A1 Szabo, Johanna A1 Dolezalova, Irena A1 Fabo, Daniel A1 Pail, Martin A1 Gutekunst, Claire-Anne A1 Migliore, Rosanna A1 Migliore, Michele A1 Lagarde, Stanislas A1 Carron, Romain A1 Karimi, Fariba A1 Astorga, Raul Castillo A1 Cassara, Antonino M. A1 Kuster, Niels A1 Neufeld, Esra A1 Bartolomei, Fabrice A1 Pedersen, Nigel P. A1 Gross, Robert E. A1 Jirsa, Viktor A1 Drane, Daniel L. A1 Brázdil, Milan A1 Williamson, Adam YR 2024 UL http://medrxiv.org/content/early/2024/12/11/2024.12.05.24303799.abstract AB Medication-refractory focal epilepsy poses a significant challenge, with approximately 30% of patients ineligible for surgery due to the involvement of eloquent cortex in the epileptogenic network. For such patients with limited surgical options, electrical neuromodulation represents a promising alternative therapy. In this study, we investigate the potential of non-invasive temporal interference (TI) electrical stimulation to reduce epileptic biomarkers in patients with epilepsy by comparing intracerebral recordings obtained before, during, and after TI stimulation, and to those recorded during low and high kHz frequency (HF) sham stimulation. Thirteen patients with symptoms of mesiotemporal epilepsy (MTLE) and implanted with stereoelectroencephalography (sEEG) depth electrodes received TI stimulation with an amplitude modulation (AM) frequency of 130Hz (Δf), where the AM was delivered with lower frequency kHz carriers (1kHz + 1.13kHz), or higher frequency carriers (9kHz + 9.13kHz), targeting the hippocampus – a common epileptic focus and consequently stimulation target in MTLE.Our results show that TI stimulation yields a statistically significant decrease in interictal epileptiform discharges (IEDs) and pathological high-frequency oscillations (HFOs) – specifically Fast-ripples (FR) –, where the suppression is apparent in the hippocampal focus and propagation from the focus is reduced brain-wide. HF sham stimulation at 1kHz frequency also impacted the IED rate in the cortex, but without reaching the hippocampal focus. The HF sham effect diminished with increasing frequencies (2, 5, and 9kHz, respectively), specifically as a function of depth into the cortex. This depth dependence was not observed with the TI, independent of the employed carrier frequency (low or high kHz). Our findings underscore the possible application of TI in epilepsy, as an additional non-invasive brain stimulation tool, potentially offering opportunities to assess brain region responses to electrical neuromodulation before committing to a deep brain stimulation (DBS) or responsive neurostimulation (RNS) implant. Our results further demonstrate distinct biophysical differences between kHz and focal AM stimulation.Competing Interest StatementN.K. and E.N. are shareholders of TI Solutions AG, a company dedicated to producing temporal interference (TI) stimulation devices to support TI research.Clinical TrialNCT06716866Funding StatementA.W. received funding from the European Union s Horizon Europe research and innovation programme under grant agreement No. 101101040 (TREATMENT) and No. 101088623 (EMUNITI). Effort on this project for both Drs. Daniel Drane and Emma Acerbo were in part supported by grants received from the National institute of Neurological Disorders and Stroke (NINDS) of the National Institutes of Healthy (NIH) [R01NS088748]. Emma Acerbo was also supported through the Emory Neuromodulation Technology Innovation Center (ENTICe).Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:The Emory IRB of Emory University, Atlanta, GA, USA gave ethical approval for this work under the number IRB00099109. The ethical committee of St. Anne's University Hospital Brno, Brno, Czech Republic gave ethical approval for this work under the number IIT/2023/25. The ethical committee of the Institute of Neurosurgery and Neurointervention, Semmelweis University, Budapest, Hungary gave ethical approval for this work under the number OGYEI/56526-2/2023. All experiments were conducted after a clinical trial registration and agreement (NCT06716866).I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.YesAll data produced in the present study are available upon request to the authors.