RT Journal Article SR Electronic T1 Deployment of a digital twin using the coupled momentum method for fluid-structure interaction: a case study for aortic aneurysm JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2024.11.07.24316881 DO 10.1101/2024.11.07.24316881 A1 Creazzo, Giacomo A1 Nannini, Guido A1 Saitta, Simone A1 Astori, Davide A1 Gaudino, Mario A1 Girardi, Leonard N. A1 Weinsaft, Jonathan W. A1 Redaelli, Alberto YR 2024 UL http://medrxiv.org/content/early/2024/11/07/2024.11.07.24316881.abstract AB Introduction Dacron graft replacement is the standard therapy for ascending aorta aneurysm, involving the insertion of a prosthesis with lower compliance than native tissue, which can alter downstream hemodynamics and lead to adverse remodeling. Digital human twins (DHT), based on in-silico models, have the potential to predict biomarkers of adverse outcome and aid in designing optimal treatments tailored to the individual patient.Objective We propose a pipeline for deploying a digital human twin of the thoracic aorta to explore alternative solutions to traditional Dacron grafting, utilizing more compliant prostheses for reconstructing the ascending aorta.Methods We propose a DHT based on fluid-structure interaction (FSI) analysis of the thoracic aorta. We create 3 models of the patient, representing: i) the pre-operative baseline, ii) the post-operative with Dacron graft, and iii) a virtual post-operative using a compliant fibrous prosthesis. 3D geometry of the thoracic aorta for a patient with a congenital aneurysm, before and after the surgery, were reconstructed from magnetic resonance imaging (MRI). As inlet boundary condition (BC), we assigned a time-varying 3D velocity profile extrapolated from 4D flow MRI. For the outlet BCs, we coupled 0D Winkler models, tuned to match the flow rate measured in the descending aorta from 4D flow. The aortic wall and the prosthetic graft were modeled as hyperelastic materials using the Holzapfel-Gasser constitutive model and tuned to patients distensibility. FSI analysis was run for two cardiac cycles.Results Results were validated against 4D flow data. Quantitative comparison of outflows between FSI and 4D flow yielded relative squared errors of 5.28% and 0.33% for models (i) and (ii), respectively. Wall shear stress (WSS) and strain increased in both post-surgical scenarios (ii) and (iii) compared to (i), with a lower increase observed in the virtual scenario (iii) (p¡0.001). However, the difference between scenarios (iii) and (ii) remained moderate on average (e.g., 0.6 Pa for WSS).Conclusions FSI analysis enables the deployment of reliable thoracic aorta DHTs to predict the impact of prostheses with different distensibility. Results indicate moderate yet promising benefits of more compliant fibrous devices on distal hemodynamics.HighlightsThe coupled momentum method for fluid-structure interaction analysis can be used to deploy a high fidelity digital twin of the aortaDacron graft induces an altered hemodynamic state in the descending aorta after ascending aorta correction.Electrowriting can be used to fabricate more compliant grafts that mitigate the adverse effect of Dacron in the descending aorta.The stress induced by a 2-folds more compliant (with respect to Dacron) graft is significantly lowerDespite the difference being relevant, it is moderate (1 Pa).Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis study did not receive any fundingAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Ethics committee of Weill Cornell Medicine College gave ethical approval for this workI confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.YesAll data produced in the present study are available upon reasonable request to the authors