PT - JOURNAL ARTICLE AU - Norris, Stanley A AU - Carrion, Daniel AU - Ditchfield, Michael AU - Gubser, Manuel AU - Seah, Jarrel AU - Badawy, Mohamed K TI - Enhancing Radiographic Diagnosis: CycleGAN-based methods for reducing cast shadow artifacts in wrist radiographs AID - 10.1101/2024.10.15.24315508 DP - 2024 Jan 01 TA - medRxiv PG - 2024.10.15.24315508 4099 - http://medrxiv.org/content/early/2024/10/24/2024.10.15.24315508.short 4100 - http://medrxiv.org/content/early/2024/10/24/2024.10.15.24315508.full AB - Objective We extend existing techniques by using generative adversarial network (GAN) models to reduce the appearance of cast shadows in radiographs across various age groups.Materials and Methods We retrospectively collected 12000 adult and pediatric wrist radiographs, evenly divided between those with and without casts. The test subset consisted of 100 radiographs with cast and 100 without cast. We extended the results from a previous study that employed CycleGAN by enhancing the model using a perceptual loss function and a self-attention layer.Results The CycleGAN model which incorporates a self-attention layer and perceptual loss function delivered the best quantitative performance. This model was applied to images from 20 cases where the original reports recommended CT scanning or repeat radiographs without the cast, which were then evaluated by radiologists for qualitative assessment. The results demonstrated that the generated images could improve radiologists’ diagnostic confidence, in some cases leading to more decisive reports. Where available, the reports from follow-up imaging were compared with those produced by radiologists reading AI-generated images. Every report, except two, provided identical diagnoses as those associated with follow-up imaging. The ability of radiologists to perform robust reporting with downsampled AI-enhanced images is clinically meaningful and warrants further investigation. Additionally, radiologists were unable to distinguish AI-enhanced from unenhanced images.Conclusion These findings suggest the cast suppression technique could be integrated as a tool to augment clinical workflows, with the potential benefits of reducing patient doses, improving operational efficiencies, reducing delays in diagnoses, and reducing the number of patient visits.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis study did not receive any fundingAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:This study was exempt from Human Research Ethics Committee review as a retrospective quality improvement project. It was consistent with the NHMRC Ethical Considerations in Quality Assurance and Evaluation Activities (2014) guideline.I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.YesAll data produced in the present study are available upon reasonable request to the authors