PT - JOURNAL ARTICLE AU - Margaryan, Rafik AU - Bianchi, Giacomo AU - Gasbarri, Tommaso AU - Concistre, Giovanni AU - Solinas, Marco TI - Titanium Fasteners In Endoscopic Mitral Valve Surgery AID - 10.1101/2020.06.03.20121400 DP - 2020 Jan 01 TA - medRxiv PG - 2020.06.03.20121400 4099 - http://medrxiv.org/content/early/2020/06/05/2020.06.03.20121400.short 4100 - http://medrxiv.org/content/early/2020/06/05/2020.06.03.20121400.full AB - Objective We sought to review our experience of new titanium knot fastener devices. We hypothesized that it might reduce the cardiop-polmonary bypass time, aortic cross-clamping time and intervention time.Materials We reviewed our electronic records in order identify the patients who underwent mitral valve (MV) repair and replacement in totally endoscopic setup. Surgical approach was trough limited right periareolar or inframmamary thoracotomy with mainly femoro-femoral arterio-venous cannulation. A part of patients underwent interventions using fast knotting system (FK group, Cor-Knot Device, ISL Solutions Inc) and remaining patients served as control group (conventional hand knotting, HK). We identified the FK patients and performed propensity score matching to match 1:1 ratio from main cohort using FK versus HK.Results A total of 306 patients underwent mitral valve repair or replacement on via right thoracotomy, 265 (87%) patients underwent using FK, remaining. There were on average 2.6 minutes of CPB time reduction (p = 0.64), and 3.1 minutes of CXC time reduction (p = 0.47). However, when dividing into procedures based on complexity, there were on average 8.6 minutes of CPB time reduction (p = 0.18), and 6.9 minutes of CXC time reduction (p = 0.16) in simple cases; on average in complex cases 12 minutes of CPB time was augmented (p = 0.24), and 2.5 minutes of CXC time was augmented(p = 0.76).In propensity matched population the effect of CPB and CXC reduction was consistent and repeated and there were on average 0.5 minutes of CPB time reduction (p = 0.12), and 3.6 minutes of CXC time augmentation (p = 0.05). However, when dividing into procedures based on complexity, there were on average 0.2 minutes of CPB time reduction (p = 0.16), and 2.7 minutes of CXC time augmentation (p = 0.06) in simple cases; on average 5 minutes of CPB time augmentation (p = 0.34), and 14.2 minutes of CXC time augmentation (p = 0.58) in complex cases.Conclusions Titanium fasteners are useful tool to have in minimally invasive approaches, especially in complex cases and redo interventions. Titanium are comfortable and fast in many cases then conventional knot tying, but it is also expensive the traditional knotting. The titanium fasteners do not offer significant time reduction. In matched group the pattern of time saving were identical to main cohort.Competing Interest StatementThe authors have declared no competing interest.Funding StatementNo funding involved in this study.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:This study was approved by local ethical committee.All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesSome data will be made available.