RT Journal Article SR Electronic T1 Electrophysiological characteristics of lead-position-dependent EGM uninterrupted transition during left bundle branch pacing JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2024.06.16.24308988 DO 10.1101/2024.06.16.24308988 A1 Shen, Jiabo A1 Jiang, Longfu A1 Wu, Hao A1 Zhang, Lu A1 Li, Hengdong A1 Pan, Lifang YR 2024 UL http://medrxiv.org/content/early/2024/06/18/2024.06.16.24308988.abstract AB Background and Aims Left bundle branch pacing (LBBP) is a novel pacing strategy that improves ventricular synchrony by utilizing the native conduction system. However, the current standard practices limit continuous monitoring of paced electrocardiogram (ECG) and intracardiac electrogram (EGM) transition, which may result in overlooked or misinterpreted subtle transitions. This study aimed to explore the electrophysiological characteristics of the lead-position-dependent EGM continuous transition and evaluate their clinical significance.Methods This observational study included patients referred for LBBP due to symptomatic bradyarrhythmia. A continuous pacing and recording technique was employed, allowing real-time monitoring of progressive alterations in the paced QRS complex as the lead penetrates deeper into the ventricular septum. EGM and ECG parameters were continuously monitored and analyzed.Results The study encompassed 105 patients, with selective LBBP achieved in 88 patients (83.8%). The amplitude of ventricular EGM predictably changed with radial interventricular septum depth and peaked in the mid-septum. As the lead was inserted into the left ventricular subendocardium, the ventricular current of injury (COI) declined to a level approximating that of the right septum. Continuous recording technique enabled real-time monitoring of the entire perforation process and the subtle variations that exist among different perforation modalities. The discernment of discrete was feasible through the examination of unfiltered EGM, suggesting that selective LBB capture can also be confirmed by observing the subtle morphological transitions within the ventricular COI.Conclusions The continuous recording technique provides a more detailed understanding of the radial depth of the pacing lead throughout the implantation process. It simplifies the implantation procedures and facilitates the prevention or early detection of perforations. Future studies are needed to validate these findings and explore their clinical implications.What’s new?Utilization of Ventricular Electrogram (EGM) for Lead Positioning: The amplitude of ventricular EGM changes predictably with radial interventricular septum depth, peaking in the mid-septum. This provides a useful way to determine whether the lead is located on the left, right, or middle of the ventricular septum.Real-time Monitoring of Perforation Process: The continuous recording technique enables real-time monitoring of the entire perforation process. This feature helps to distinguish the subtle variations that exist among different perforation modalities, facilitating early detection and prevention of perforations.Confirmation of Selective Left Bundle Branch Pacing (SLBBP): The emergence of a discrete ventricular current of injury (COI) may serve as a novel characteristic of SLBBP. This suggests that SLBBP can be confirmed by observing the subtle morphological transitions within the ventricular COI.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis work was supported by the Ningbo Public Service Technology Foundation [grant number 2023S089], Zhejiang Provincial Public Service and Application Research Foundation, China [grant number LGF22H020009], and Zhu Xiu Shan Talent Project of Ningbo No.2 Hospital, China [grant number 2023HMYQ18].Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:The research protocol was approved by the Institutional Review Board of Ningbo No.2 Hospital, and informed consent was duly obtained from each participant.I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.YesAll data produced in the present study are available upon reasonable request to the authors