PT - JOURNAL ARTICLE AU - Koizumi, Satoshi AU - Kin, Taichi AU - Sekine, Tetsuro AU - Kiyofuji, Satoshi AU - Umekawa, Motoyuki AU - Saito, Nobuhito TI - Intracranial aneurysm stiffness assessment using 4D flow MRI AID - 10.1101/2024.04.05.24302112 DP - 2024 Jan 01 TA - medRxiv PG - 2024.04.05.24302112 4099 - http://medrxiv.org/content/early/2024/04/09/2024.04.05.24302112.short 4100 - http://medrxiv.org/content/early/2024/04/09/2024.04.05.24302112.full AB - Background Although arterial stiffness is a known biomarker for cardiovascular events and stroke, there is limited information in the literature regarding the stiffness of intracranial aneurysms. This study aimed to assess intracranial aneurysm stiffness using four-dimensional flow magnetic resonance imaging (4D flow MRI).Methods A total of 27 aneurysms in 25 patients with internal carotid artery aneurysms were included. Using 4D flow MRI, we measured the arterial pulse waveform during a cardiac cycle at planes proximal and distal to the target aneurysm. The damping of these waveforms through the aneurysm was defined as the aneurysm damping index (ADI) and compared with that of the contralateral side. Additionally, we investigated the clinical factors associated with the ADI.Results ADI assessment was successful in all cases. The obtained ADI was 1.18 ± 0.28 (mean ± standard deviation), significantly larger than 1.0 (P=0.0027 [t-test]). The ADI on the aneurysm side was larger than on the contralateral side (1.19 ± 0.30 vs 1.05 ± 0.17, P=0.029 [t-test]). On multivariate analysis, the use of beta-blockers (β=0.46, P=0.015) and smoking history (β=-0.22, P=0.024) showed a significant correlation with ADI.Conclusions We proposed a novel method to assess the stiffness of intracranial aneurysms using 4D flow MRI. The quantitative observation of the damping of arterial pulse waves revealed a correlation between ADI and clinical factors, such as the use of antihypertensive drugs and smoking. Further studies should focus on evaluating the aneurysm stiffness and its clinical applications.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis study was supported by a grant from SENSHIN Medical Research Foundation.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:IRB of the University of Tokyo Hospital gave ethical approval for this workI confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.YesThe datasets generated and/or analyzed during the current study are available from the corresponding author on reasonable request.ADIAneurysm Damping IndexMRIMagnetic Resonance ImagingPIPulsatility IndexFOVField of ViewTOF-MRATime-of-Flight Magnetic Resonance AngiographyTRRepetition TimeTEEcho Time