RT Journal Article SR Electronic T1 Precision Brain Morphometry Using Cluster Scanning JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2023.12.23.23300492 DO 10.1101/2023.12.23.23300492 A1 Elliott, Maxwell L. A1 Nielsen, Jared A. A1 Hanford, Lindsay C. A1 Hamadeh, Aya A1 Hilbert, Tom A1 Kober, Tobias A1 Dickerson, Bradford C. A1 Hyman, Bradley T. A1 Mair, Ross W. A1 Eldaief, Mark C. A1 Buckner, Randy L. YR 2023 UL http://medrxiv.org/content/early/2023/12/28/2023.12.23.23300492.abstract AB Measurement error limits the statistical power to detect group differences and longitudinal change in structural MRI morphometric measures (e.g., hippocampal volume, prefrontal thickness). Recent advances in scan acceleration enable extremely fast T1-weighted scans (∼1 minute) to achieve morphometric errors that are close to the errors in longer traditional scans. As acceleration allows multiple scans to be acquired in rapid succession, it becomes possible to pool estimates to increase measurement precision, a strategy known as “cluster scanning.” Here we explored brain morphometry using cluster scanning in a test-retest study of 40 individuals (12 younger adults, 18 cognitively unimpaired older adults, and 10 adults diagnosed with mild cognitive impairment or Alzheimer’s Dementia). Morphometric errors from a single compressed sensing (CS) 1.0mm scan with 6x acceleration (CSx6) were, on average, 12% larger than a traditional scan using the Alzheimer’s Disease Neuroimaging Initiative (ADNI) protocol. Pooled estimates from four clustered CSx6 acquisitions led to errors that were 34% smaller than ADNI despite having a shorter total acquisition time. Given a fixed amount of time, a gain in measurement precision can thus be achieved by acquiring multiple rapid scans instead of a single traditional scan. Errors were further reduced when estimates were pooled from eight CSx6 scans (51% smaller than ADNI). Neither pooling across a break nor pooling across multiple scan resolutions boosted this benefit. We discuss the potential of cluster scanning to improve morphometric precision, boost statistical power, and produce more sensitive disease progression biomarkers.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis research was supported by NIA grants R01AG067420, R01DC014296 and P30AG062421, NIH Shared Instrumentation Grant S10OD020039, and Simons Foundation grant 811255. M.L.E. is supported by NIA grant K00AG068432.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:The study protocol was approved by the Institutional Review Board of Mass General Brigham Healthcare who gave ethical approval for this work. All participants provided written informed consent in accordance with the guidelines of the Institutional Review Board of Mass General Brigham Healthcare and were compensated.I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.YesMRI data used in this manuscript will be made available and the analysis code will be available on GitHub.