PT - JOURNAL ARTICLE AU - Jin, Shuo AU - Wang, Bo AU - Xu, Haibo AU - Luo, Chuan AU - Wei, Lai AU - Zhao, Wei AU - Hou, Xuexue AU - Ma, Wenshuo AU - Xu, Zhengqing AU - Zheng, Zhuozhao AU - Sun, Wenbo AU - Lan, Lan AU - Zhang, Wei AU - Mu, Xiangdong AU - Shi, Chenxin AU - Wang, Zhongxiao AU - Lee, Jihae AU - Jin, Zijian AU - Lin, Minggui AU - Jin, Hongbo AU - Zhang, Liang AU - Guo, Jun AU - Zhao, Benqi AU - Ren, Zhizhong AU - Wang, Shuhao AU - You, Zheng AU - Dong, Jiahong AU - Wang, Xinghuan AU - Wang, Jianming AU - Xu, Wei TI - AI-assisted CT imaging analysis for COVID-19 screening: Building and deploying a medical AI system in four weeks AID - 10.1101/2020.03.19.20039354 DP - 2020 Jan 01 TA - medRxiv PG - 2020.03.19.20039354 4099 - http://medrxiv.org/content/early/2020/03/23/2020.03.19.20039354.short 4100 - http://medrxiv.org/content/early/2020/03/23/2020.03.19.20039354.full AB - The sudden outbreak of novel coronavirus 2019 (COVID-19) increased the diagnostic burden of radiologists. In the time of an epidemic crisis, we hoped artificial intelligence (AI) to help reduce physician workload in regions with the outbreak, and improve the diagnosis accuracy for physicians before they could acquire enough experience with the new disease. Here, we present our experience in building and deploying an AI system that automatically analyzes CT images to detect COVID-19 pneumonia features. Different from conventional medical AI, we were dealing with an epidemic crisis. Working in an interdisciplinary team of over 30 people with medical and / or AI background, geographically distributed in Beijing and Wuhan, we were able to overcome a series of challenges in this particular situation and deploy the system in four weeks. Using 1,136 training cases (723 positives for COVID-19) from five hospitals, we were able to achieve a sensitivity of 0.974 and specificity of 0.922 on the test dataset, which included a variety of pulmonary diseases. Besides, the system automatically highlighted all lesion regions for faster examination. As of today, we have deployed the system in 16 hospitals, and it is performing over 1,300 screenings per day.Competing Interest StatementBo Wang is the co-founder and chief executive officer (CEO) of Beijing Jingzhen Medical Technology Ltd. Wei Zhao is the chief technology officer (CTO) of Beijing Jingzhen Medical Technology Ltd. Hongbo Jin, Wei Zhao, Wei Zhang, Xuexue Hou, Zhengqing Xu, and Zijian Jin are the algorithm and system researchers of Beijing Jingzhen Medical Technology Ltd. All remaining authors have declared no conflicts of interest.Funding StatementThis work is supported by National Key Research and Development Program of China No. 2020YFC0845500, National Natural Science Foundation of China (NSFC) No. 61532001, Tsinghua Initiative Research Program Grant No. 20151080475, Application for Independent Research Project of Tsinghua University (Project Against SARI).Author DeclarationsAll relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.YesAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesPlease contact the authors for data availability.