RT Journal Article SR Electronic T1 Helium optically pumped magnetometers can detect epileptic abnormalities as well as SQUIDs as shown by intracerebral recordings JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2023.10.24.23297371 DO 10.1101/2023.10.24.23297371 A1 Badier, Jean-Michel A1 Schwartz, Denis A1 Bénar, Christian-George A1 Kanzari, Khoubeib A1 Daligault, Sébastien A1 Romain, Rudy A1 Mitryukovskiy, Sergey A1 Fourcault, William A1 Josselin, Vincent A1 Prado, Matthieu Le A1 Jung, Julien A1 Palacios-Laloy, Augustin A1 Carron, Romain A1 Bartolomei, Fabrice A1 Labyt, Etienne A1 Bonini, Francesca YR 2023 UL http://medrxiv.org/content/early/2023/10/25/2023.10.24.23297371.abstract AB SQUID-based magnetoencephalography has been shown to improve the diagnosis and surgical treatment decision for presurgical evaluation of drug-resistant epilepsy. Still, its use remains limited due to several constraints such as cost, fixed helmet size and obligation of immobility. A new generation of sensors, the optically pumped magnetometers (OPMs), could overcome these limitations. In this study, we validate the ability of innovative Helium-based OPM (4He-OPM) sensors to record epileptic brain activity thanks to simultaneous recordings with intracerebral EEG (stereotactic EEG, SEEG). We recorded simultaneous SQUIDs-SEEG and 4He-OPM-SEEG signals in one patient during two sessions. We show that epileptic activities on intracerebral EEG can be recorded by OPMs with a better signal-to noise ratio than classical SQUIDs. The OPM sensors open new venues for the widespread application of magnetoencephalography in the management of epilepsy and other neurological diseases and fundamental neuroscience.Significance Statement We performed a simultaneous recording of Helium-based Optically Pumped Magnetometers (OPM) and intracerebral EEG and validate for the first time OPM results with signals recorded directly within the brain. We demonstrate that epileptic abnormalities seen on intracerebral electrodes are detected by OPMs with a better signal-to noise ratio than classical magnetoencephalography. This represents a significant step towards the validation of OPM-based recordings for epilepsy diagnosis and for clinical and neuroscience research.Competing Interest StatementEL, APL, ML, holds founding equity in Mag4Health, a CEA-LETI spin off company whose aim is to commercialize Helium OPM based MEG systems. The remaining authors have no conflicts of interest.Funding StatementThis study was funded by AP-HM and CEA-LETIAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:The ethical approval was obtained at the AssistancePublique - Hopitaux de Marseille (AP-HM) under IDRCB 2020-A01830-39 and the patient gave informed written consentI confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.YesAll data produced in the present study are available upon reasonable request to the authors