RT Journal Article SR Electronic T1 COVision: Convolutional Neural Network for the Differentiation of COVID-19 from Common Pulmonary Conditions Using CT Scans JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2023.01.22.23284880 DO 10.1101/2023.01.22.23284880 A1 Parikh, Kush V. A1 Mathew, Timothy J. YR 2023 UL http://medrxiv.org/content/early/2023/10/23/2023.01.22.23284880.abstract AB With the growing amount of COVID-19 cases, especially in developing countries with limited medical resources, it is essential to accurately and efficiently diagnose COVID-19. Due to characteristic ground-glass opacities (GGOs) and other types of lesions being present in both COVID-19 and other acute lung diseases, misdiagnosis occurs often — 26.6% of the time in manual interpretations of CT scans. Current deep-learning models can identify COVID-19 but cannot distinguish it from other common lung diseases like bacterial pneumonia. Concretely, COVision is a deep-learning model that can differentiate COVID-19 from other common lung diseases, with high specificity using CT scans and other clinical factors. COVision was designed to minimize overfitting and complexity by decreasing the number of hidden layers and trainable parameters while still achieving superior performance. Our model consists of two parts: the CNN which analyzes CT scans and the CFNN (clinical factors neural network) which analyzes clinical factors such as age, gender, etc. Using federated averaging, we ensembled our CNN with the CFNN to create a comprehensive diagnostic tool. After training, our CNN achieved an accuracy of 95.8% and our CFNN achieved an accuracy of 88.75% on a validation set. We found a statistical significance that COVision performs better than three independent radiologists with at least 10 years of experience, especially in differentiating COVID-19 from pneumonia. We analyzed our CNN’s activation maps through Grad-CAMs and found that lesions in COVID-19 presented peripherally, closer to the pleura, whereas pneumonia lesions presented centrally.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis study did not receive any funding.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:1) Consortium of Chest CT Image Investigation (CC-CCII) Dataset: http://ncov-ai.big.ac.cn/download?lang=en 2) Khorshid COVID Cohort (KCC): https://doi.org/10.6084/m9.figshare.16682422.v1 3) Israeli Ministry of Health: https://data.gov.il/dataset/covid-19/resource/74216e15-f740-4709-adb7-a6fb0955a048 The CT Scans of COVID-19, pneumonia, and healthy patients were obtained from the China Consortium of Chest CT Image Investigation (CC-CCII) dataset. Ground truth for the CC-CCII dataset was established via serology tests and confirmed by laboratory findings. Clinical factors for COVID-19 and pneumonia patients were obtained from the Khorshid COVID Cohort (KCC). Clinical factors for healthy patients were obtained from the Israeli Ministry of Health public dataset. We compiled all the clinical factors data into a CSV file using the pandas and NumPy libraries in Python. We removed the clinical factors from the dataset that were not one of the following: shortness of breath, cough, headache, fever, sore throat, age, and gender. We binarized the ages of the patients by having a threshold age of 60 years (1 assigned to age if the age is greater than 60 years, 0 assigned if the age is less than 60 years). I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data produced are available online at: 1) Consortium of Chest CT Image Investigation (CC-CCII) Dataset: http://ncov-ai.big.ac.cn/download?lang=en 2) Khorshid COVID Cohort (KCC): https://doi.org/10.6084/m9.figshare.16682422.v1 3) Israeli Ministry of Health: https://data.gov.il/dataset/covid-19/resource/74216e15-f740-4709-adb7-a6fb0955a048 http://ncov-ai.big.ac.cn/download?lang=en https://doi.org/10.6084/m9.figshare.16682422.v1 https://data.gov.il/dataset/covid-19/resource/74216e15-f740-4709-adb7-a6fb0955a048