RT Journal Article SR Electronic T1 Fusion of Electronic Health Records and Radiographic Images for a Multimodal Deep Learning Prediction Model of Atypical Femur Fractures JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2023.07.02.23292125 DO 10.1101/2023.07.02.23292125 A1 Schilcher, Jörg A1 Nilsson, Alva A1 Andlid, Oliver A1 Eklund, Anders YR 2023 UL http://medrxiv.org/content/early/2023/07/03/2023.07.02.23292125.abstract AB Atypical femur fractures (AFF) represent a very rare type of fracture that can be difficult to discriminate radiologically from normal femur fractures (NFF). AFFs are associated with drugs that are administered to prevent osteoporosis-related fragility fractures, which are highly prevalent in the elderly population. Given that these fractures are rare and the radiologic changes are subtle currently only 7% of AFFs are correctly identified, which hinders adequate treatment for most patients with AFF. Deep learning models could be trained to classify automatically a fracture as AFF or NFF, thereby assisting radiologists in detecting these rare fractures. Historically, for this classification task, only imaging data have been used, using convolutional neural networks (CNN) or vision transformers applied to radiographs. However, to mimic situations in which all available data are used to arrive at a diagnosis, we adopted an approach of deep learning that is based on the integration of image data and tabular data (from electronic health records) for 159 patients with AFF and 914 patients with NFF. We hypothesized that the combinatorial data, compiled from all the radiology departments of 72 hospitals in Sweden and the Swedish National Patient Register, would improve classification accuracy, as compared to using only one modality. At the patient level, the area under the ROC curve (AUC) increased from 0.966 to 0.987 when using the integrated set of imaging data and seven pre-selected variables, as compared to only using imaging data. More importantly, the sensitivity increased from 0.796 to 0.903. We found a greater impact of data fusion when only a randomly selected subset of available images was used to make the image and tabular data more balanced for each patient. The AUC then increased from 0.949 to 0.984, and the sensitivity increased from 0.727 to 0.849. These AUC improvements are not large, mainly because of the already excellent performance of the CNN (AUC of 0.966) when only images are used. However, the improvement is clinically highly relevant considering the importance of accuracy in medical diagnostics. We expect an even greater effect when imaging data from a clinical workflow, comprising a more diverse set of diagnostic images, are used.Competing Interest StatementAnders Eklund has previously received graphics hardware from Nvidia.Funding StatementAnders Eklund was supported by the ITEA/VINNOVA funded project Automation, Surgery Support and Intuitive 3D visualization to optimize the workflow in image-guided therapy (IGT) SysTems (ASSIST) (grant no. 2021-01954). Jorg Schilcher has received ALF funding from Region Ostergotland and generous support from the Knut and Alice Wallenberg Foundation.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:This research study was approved by the Swedish ethical review authority (Dnr. 2021-06482-02).I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.YesWe have shared our code on Github: https://github.com/wanderine/AFF_fusion . To share multimodal data is difficult for anonymization purposes.