RT Journal Article SR Electronic T1 Detection of dynamic lung hyperinflation using cardiopulmonary exercise testing and respiratory function in patients with stable cardiac disease: a multicenter cross-sectional study JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2023.04.27.23289236 DO 10.1101/2023.04.27.23289236 A1 Kominami, Kazuyuki A1 Noda, Kazuki A1 Minagawa, Nanaho A1 Yonezawa, Kazuya A1 Ueda, Masanori A1 Kobayashi, Yasuyuki A1 Murata, Makoto A1 Akino, Masatoshi YR 2023 UL http://medrxiv.org/content/early/2023/05/01/2023.04.27.23289236.abstract AB Background Many patients with heart disease potentially have comorbid COPD, however there are not enough opportunities for screening and the qualitative differentiation of shortness of breath (SOB) has not been well established. We investigated the detection rate of SOB based on a visual and qualitative dynamic lung hyperinflation (DLH) detection index during cardiopulmonary exercise testing (CPET) and whether there was a difference in respiratory function between the two groups.Methods We recruited 534 patients with heart disease and to scrutinize physical functions (369 males, 67.0±12.9 years) who underwent CPET and spirometry simultaneously. The difference between inspiratory and expiratory tidal volume was calculated (TV E-I) from the breath-by-breath data. A TV E-I decrease after the start of exercise comprised the convex group, and a TV E-I that remained unchanged or increased comprised the non-convex group.Results 129 patients (24.2%) were in the convex; there was no difference in clinical characteristics between groups. The Borg scale scores at the end of the CPET showed no difference. VE/VCO2 slope, its Y-intercept and minimum VE/VCO2 showed no significant difference. In the convex group, FEV1.0% was significantly lower (69.4±13.1 vs. 75.0±9.0%), and FEV1.0% and Y-intercept and the difference between minimum VE/VCO2 and VE/VCO2 slope were significantly correlated (r=−0.343 and r=−0.478).Conclusions The convex group showed decreased respiratory function, suggesting potential airway obstruction during exercise. A combined assessment of the TV E-I and Y-intercept of the VE/VCO2 slope or the difference between the minimum VE/VCO2 and VE/VCO2 slopes could potentially detect COPD or airway obstruction.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis study did not receive any funding support.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:The study was conducted following the principles outlined in the Declaration of Helsinki and was approved by the ethics committees of Hakodate National Hospital (approval number: R4-1114006) and the Gunma Prefectural Cardiovascular Center (approval number:2022020). The data obtained were delinked and anonymized, and this study was conducted using the data for analysis and due consideration to the protection of the participants? personal information. Consequently, the authors confirmed that none of the participants could be identified, and they were fully anonymized. Furthermore, the authors affirm that all mandatory health and safety procedures complied with the course of conducting the experimental work reported in this paper.I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.YesThe dataset used in this study is available from the corresponding author upon request.VATventilatory anaerobic thresholdInc-Exincremental exerciseCPETCardiopulmonary exercise testingVO2Oxygen uptakeVCO2carbon dioxide productionVEventilatory equivalentRPERating of perceived exertionRRrespiratory rateVD/VTdead-space gas volume to tidal volume ratioCOPDchronic obstructive pulmonary diseaseDLHdynamic lung hyperinflationTVtidal volumeTV Iinspiratory tidal volumeTV Eexpiratory tidal volumeFEVforced expiratory volumeFEV1.0forced expiratory volume in 1 secondFEV 1.0%forced expiratory volume in 1 second as a percent of forced vital capacityVCvital capacityICinspiratory capacity