PT - JOURNAL ARTICLE AU - Wafula, Solomon T. AU - Nalugya, Aisha AU - Mendoza, Hilbert AU - Kansiime, Winnie K AU - Ssekamatte, Tonny AU - Walekhwa, Abel Wilson AU - Mugambe, Richard K. AU - Walter, Florian AU - Ssempebwa, John C AU - Musoke, David TI - Indoor air pollutants and respiratory outcomes among residents of an informal urban setting in Uganda: a cross-sectional study AID - 10.1101/2022.07.28.22278151 DP - 2022 Jan 01 TA - medRxiv PG - 2022.07.28.22278151 4099 - http://medrxiv.org/content/early/2022/07/31/2022.07.28.22278151.short 4100 - http://medrxiv.org/content/early/2022/07/31/2022.07.28.22278151.full AB - Background Indoor air pollutants (IAP) such as particulate matter (PM) and carbon monoxide (CO) are a leading cause of acute respiratory symptoms, and long-term health impacts such as respiratory diseases, heart diseases and cancers. In Uganda, literature on the effects of IAP on respiratory outcomes in informal settlements is limited. This study investigated the association of selected IAPs and cooking fuels with respiratory symptoms among children and adults.Methods This study was conducted among 284 households in an informal settlement in Uganda from April to May 2022. Information on indoor air conditions, fuel type and adults reported the respiratory symptoms of their children as well as their respiratory symptoms within the previous 30 days. Same-day concentrations of PM less than 2.5 μm (PM2.5) and less than 10 μm(PM10) in diameter were monitored from 9 am to 2 pm using Temptop M2000c 2nd edition particle sensor while CO was measured using a carbon monoxide meter. Robust Poisson regression was used to model the associations between indoor air conditions, fuel type and respiratory health outcomes.Results Approximately 94.7% of the households were using biomass fuels. Cough (66.2%), shortness of breath (33.5%) and phlegm (17.6%) were common respiratory symptoms in adults while in children, morning cough (80.0%), day or night cough (34.4%) and shortness of breath (26.5%) were reported. The median PM2.5, PM10 and CO levels were 49.5(IQR= 31.1, 86.2) µg/m3, 73.6(IQR= 47.3,130.5) µg/m3 and 7.7(IQR= 4.1,12.5) ppm respectively. Increase in humidity was associated with higher levels of PM2.5 (ß = 2.74, p =0.004) and PM10 (ß= 4.14, p =0.002) however temperature increases were associated with lower levels of PM2.5 (ß = -11.72, p =0.009) and PM10 (ß= -16.36, p =0.008) but higher CO levels (ß=2.24, p = 0.032). Use of less polluting fuels such as electricity and gas were associated with low levels of PM2.5 (ß= -31.36, 95%CI =-60.7 – -2.02) while home dampness (ß = 3.39, 95%CI =0.07 – 6.72) was associated with higher indoor CO levels. Dampness was associated with acute phlegm in adults (PR= 2.78, 95%CI =1.57 – 4.90) and outdoor cooking was found to be associated with lower shortness of breath risk (PR = 0.60,95%CI =0.40 – 0.91).Conclusion The prevalence of respiratory problems among adults and children was high. Poor indoor air conditions were associated with respiratory symptoms in adults and children. Efforts should be made to protect adults and children from the adverse effects of indoor air pollution.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis study was funded by Makerere University School of Public Health under the Small Grants Programme, MakSPH-GRCB/18-19/01/02Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.Not ApplicableThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Ethical approval to conduct the study was obtained from Makerere University School of Public Health Higher Degrees Research and Ethics Committee (HDREC: Ref No. SPH-2021-99) and the Uganda National Council of Science and Technology (UNCST: Ref No. SS996ES). Confidentiality and anonymity were assured to the participants and their information. Written informed consent was obtained from each participant, children were not interviewed but their information was reported by parents/guardiansI confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.Not ApplicableI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).Not ApplicableI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.Not ApplicableData are available from the corresponding author upon reasonable request