RT Journal Article SR Electronic T1 Deep-learning-based automatic detection of pulmonary nodules from chest radiographs JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2022.06.21.22276691 DO 10.1101/2022.06.21.22276691 A1 Ajmera, Pranav A1 Pant, Richa A1 Seth, Jitesh A1 Ghuwalewala, Suraj A1 Kathuria, Sahil A1 Rathi, Snehal A1 Patil, Sonali A1 Edara, Manaswani A1 Saini, Mukul A1 Raj, Preeti A1 Duddalwar, Vinay A1 Kulkarni, VM A1 Patil, Parag A1 Kulkarni, Viraj A1 Kharat, Amit YR 2022 UL http://medrxiv.org/content/early/2022/06/29/2022.06.21.22276691.abstract AB Objective To assess a deep learning-based artificial intelligence model for the detection of pulmonary nodules on chest radiographs and to compare its performance with board-certified human readers.Methods For this retrospective study, 308 chest radiographs were obtained between January 2019 to December 2021 from a tertiary care hospital. All radiographs were analyzed using a deep learning AI model called DxNodule AI Screen. Two expert board-certified radiologists established the ground truth, and 11 test readers independently reviewed all radiographs in two sessions (unaided and AI-aided mode) with a washout period of one month.Results The standalone model had an AUROC of 0.905 [0.87, 0.94] in detecting pulmonary nodules. The mean AUROC across the 11 readers improved from 0.798 [0.74, 0.86] for unaided interpretation to 0.846 [0.82, 0.880] for AI-aided interpretation. With DxNodule AI Screen, readers were able to identify nodules at the correct locations, which they otherwise missed. The mean specificity, accuracy, PPV, and NPV of the readers improved significantly from 0.87 [0.78, 0.96], 0.78 [0.72, 0.84], 0.77 [0.65, 0.88], and 0.86 [0.81, 0.90] in the unaided session to 0.89 [0.82, 0.96], 0.83 [0.80, 0.85], 0.82 [0.73, 0.9], and 0.89 [0.86, 0.92], respectively in the aided session.Conclusion DxNodule AI Screen outperformed human readers in nodule detection performance on chest radiographs, and enhanced human readers’ performances when used as an aid.Competing Interest StatementAmit Kharat is a Professor at Dr. DY Patil Medical College, Pune, and is also a co-founder of DeepTek Medical Imaging Pvt Ltd. Vinay Duddalwar is a Professor of Radiology at Keck School of Medicine, USC, USA, and is also on the advisory board of DeepTek Medical Imaging Pvt Ltd. He is a consultant to Radmetrix Inc, Cohere Inc, and Westat Inc.Funding StatementThis study did not receive any fundingAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Ethics committee of Dr. D.Y. Patil hospital and research center gave ethical approval for this workI confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data produced in the present work are contained in the manuscript