RT Journal Article SR Electronic T1 Evaluation of the second-generation whole-heart motion correction algorithm (SSF2) used to demonstrate the aortic annulus on cardiac CT JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2022.06.28.22276816 DO 10.1101/2022.06.28.22276816 A1 Matsumoto, Yoriaki A1 Fujioka, Chikako A1 Yokomachi, Kazushi A1 Kitera, Nobuo A1 Nishimaru, Eiji A1 Kiguchi, Masao A1 Higaki, Toru A1 Kawashita, Ikuo A1 Tatsugami, Fuminari A1 Nakamura, Yuko A1 Awai, Kazuo YR 2022 UL http://medrxiv.org/content/early/2022/06/28/2022.06.28.22276816.abstract AB Purpose To investigate the usefulness of the second-generation whole-heart motion correction algorithm (SnapShot Freeze 2.0, SSF2) for demonstrating the aortic annulus at pre-transcatheter aortic valve implantation cardiac CT.Method We retrospectively analyzed 90 patients with severe aortic stenosis who had undergone cardiac CT on a 256-row CT scanner. The patients were divided into the 3 groups based on their heart rate during the scan (low, < 60 bpm, n = 30; intermediate, 60-69 bpm, n = 30; high, >70 bpm, n = 30). Image datasets were obtained at 40% and 75% of the R-R interval using standard and SSF2 reconstruction. The edge rise distance (ERD) on the CT attenuation profile of the aortic annulus was compared on images subjected to standard- and SSF2 reconstructions. The standard deviations (SD) of area and perimeter were compared using the F-test. The image quality was assessed by two observers using a 5-point Likert score.Results In patients with intermediate and high heart rates, the ERD was significantly shorter on SSF2- than standard reconstructed images (p < 0.01). The SD of area and perimeter were significantly smaller in SSF2 reconstruction than in standard (all: p < 0.05). Except for R-R interval 75% in patients with low heart rate (p = 0.54), the image quality scores were significantly higher for images reconstructed with SSF2 than standard (p < 0.01).Conclusions For the demonstration of the aortic annulus in patients with high heart rate or a 40% R-R interval, SSF2- was superior to standard reconstruction.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThe authors received no specific funding for this work.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:The institutional ethics committee approved this study protocol, which adhered to the ethical guidelines of the Declaration of Helsinki (Ethical Committee for Clinical Research of Hiroshima University, No. E-2623).I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data produced in the present work are contained in the manuscript. file:///C:/Users/yoriakimatsumoto/Desktop/SSF2%20aortic%20annulus/6-1Plos%20One/Supporting%20Information.htm bpmbeats per minuteCTcomputed tomographyCNRcontrast-to-noise ratioERDedge rise distanceMPRmultiplanar reconstructionROIregion of interestSDstandard deviationSSFSnapShot FreezeTAVItranscatheter aortic valve implantation