RT Journal Article SR Electronic T1 Blood Draw Site and Analytic Device Influence Hemoglobin Measurements JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2022.04.09.22273541 DO 10.1101/2022.04.09.22273541 A1 Killilea, David W. A1 Kuypers, Frans A. A1 Larkin, Sandra K. A1 Schultz, Kathleen YR 2022 UL http://medrxiv.org/content/early/2022/04/13/2022.04.09.22273541.abstract AB Anemia is a continuing global public health concern and a priority for international action. The prevalence of anemia is estimated from the hemoglobin (Hb) levels within target populations, yet the procedures for measuring Hb are not standardized and different approaches may result in discrepancies. Several analytical variables have been proposed to influence Hb measurements, but it is difficult to understand the impact on specific variables from large population or field studies. Therefore, we designed a highly controlled protocol that minimized most technical parameters to specifically investigate the impact of blood draw site and analytic device on Hb measurements. A diverse cohort of sixty healthy adults each provided a sequential capillary and venous blood sample that were measured for Hb using an automated hematology analyzer (ADVIA-2120) and two point-of-care devices (HemoCue 201+ and HemoCue 301). Comparing blood draw sites, the mean Hb content was 0.32-0.47 g/dL (2-4%) higher in capillary compared to venous blood from the same donors. Comparing different Hb measuring instruments, the mean Hb content was 0.19-0.46 g/dL (1-4%) higher measured with HemoCue devices compared to ADVIA-2120 in both capillary and venous blood from the same donors. The maximum variance in measurement was also higher with HemoCue devices using blood from venous (5-6% CV) and capillary (21-25% CV) sites compared to ADVIA-2120 (0.6-2% CV). Other variables including blood collection tube manufacturer did not affect mean Hb content. These results demonstrate that even when most technical variables are minimized, the blood draw site and the analytical device can have a small but statistically significant effect on the mean and dispersion of Hb measurements. Even in this study, the few participants identified as mildly anemic using venous blood measured by ADVIA-2120 would not have been classified as anemic using their capillary blood samples or point-of-care analyzers. Thus, caution is warranted when comparing Hb values between studies having differences in blood draw site and Hb measuring device. Future anemia testing should maintain consistency in these analytical variables.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis study was funded by the Bill & Melinda Gates Foundation (OPP1178834).Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:The Childrens Hospital Oakland Research Institute Institutional Review Board gave ethical approval for this work (2019-055).I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data produced in the present study are available upon reasonable request to the authors.ANOVAanalysis of variance testBCTblood collection tubeBDBecton, Dickinson and CompanyCBCcomplete blood countCHORIChildren’s Hospital Oakland Research InstituteCVcoefficient of variationK2EDTAdipotassium ethylenediaminetetraacetic acidK3EDTAtripotassium ethylenediaminetetraacetic acidHbhemoglobinLMIClow and middle-income countriesNHANESNational Health and Nutrition Examination SurveysPOCpoint-of-careWHOWorld Health Organization