RT Journal Article SR Electronic T1 Ventricular and Atrial Pressure-Volume Loops: Analysis of the Effects Induced by Right Centrifugal Pump Assistance JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2022.03.22.22272760 DO 10.1101/2022.03.22.22272760 A1 De Lazzari, Beatrice A1 Iacovoni, Attilio A1 Capoccia, Massimo A1 Papa, Silvia A1 Badagliacca, Roberto A1 Vizza, Carmine Dario A1 De Lazzari, Claudio YR 2022 UL http://medrxiv.org/content/early/2022/03/23/2022.03.22.22272760.abstract AB Background and Objective The main indications for right ventricular assist device (RVAD) support are right heart failure after implantation of a left ventricular assist device (LVAD) or early graft failure following heart transplantation. About 30-40% of patients will need RVAD support after LVAD implantation. Pulmonary hypertension is also an indication for right heart assistance. Several types of RVAD generating pulsatile or continuous flow are available on the market. These assist devices can be connected to the cardiovascular system in different ways. We sought to analyse the effects induced by different RVAD connections when right ventricular elastance is modified using a numerical simulator. The analysis was based on the behaviour of both left and right ventricular and atrial loops in the pressure-volume plane.Methods New modules of the cardiovascular network and a right ventricular centrifugal pump were implemented in CARDIOSIM© software simulator platform. The numerical pump model generated continuous flow when connected in series or parallel to the right ventricle. When the RVAD was connected in series (parallel), the pump removed blood from the right ventricle (atrium) and ejected it into the pulmonary artery. In our study, we analysed the effects induced by RVAD support on left/right ventricular/atrial loops when right ventricular elastance slope (EesRIGHT) changed from 0.3 to 0.8 mmHg/ml with the pump connected either in series or parallel. The effect of low and high rotational pump speed was also addressed.Results Percentage changes up to 60% were observed for left ventricular pressure-volume area and external work during in-parallel RVAD support at 4000 rpm with EesRIGHT = 0.3mmHg/ml. The same pump setting and connection type led to percentage variation up to 20% for left ventricular ESV and up to 25% for left ventricular EDV with EesRIGHT = 0.3mmHg/ml. Again the same pump setting and connection generated up to 50% change in left atrial pressure-volume loop area (PVLAL-A) and only 3% change in right atrial pressure-volume loop area (PVLAR-A) when EesRIGHT = 0.3mmHg/ml. Percentage variation was lower when EesRIGHT was increased up to 0.8 mmHg/ml.Conclusion Early recognition of right ventricular failure followed by aggressive treatment is desirable to achieve a more favourable outcome. RVAD support remains an option for advanced right ventricular failure although onset of major adverse events may preclude its use.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis study did not receive any fundingAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesI confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data produced in the present study are available upon reasonable request to the authors