PT - JOURNAL ARTICLE AU - Meng, Qinglin AU - Zhou, Huali AU - Lu, Thomas AU - Zeng, Fan-Gang TI - Gaussian-Enveloped Tones (GET): a vocoder that can simulate pulsatile stimulation in cochlear implants AID - 10.1101/2022.02.21.22270929 DP - 2022 Jan 01 TA - medRxiv PG - 2022.02.21.22270929 4099 - http://medrxiv.org/content/early/2022/03/03/2022.02.21.22270929.short 4100 - http://medrxiv.org/content/early/2022/03/03/2022.02.21.22270929.full AB - Acoustic simulations of cochlear implants allow comprehensive evaluation of not only perceptual performance under impoverished listening conditions but also relative contributions of classical spectral and temporal cues to speech recognition. Conventional simulations use continuous sinusoidal or noise carriers, lacking the vital pulsatile characteristics in a typical cochlear-implant processing strategy. The present study employed Gaussian-enveloped tones (GETs) as a discrete carrier to simulate the electric pulse train in modern cochlear implants. Two types of GET vocoders were implemented and evaluated in normal-hearing listeners to compare their performance to actual cochlear-implant performance. In the first implementation, GETs with different durations were used to simulate electric current interaction across channels that produced vowel and consonant recognition similar to the actual cochlear-implant result. In the second implementation, a direct mapping from electric pulses to GETs was developed to simulate a widely-used clinical n-of-m strategy in cochlear implants. The GET processing simulated the actual implant speech in noise perception in terms of the overall trend, the absolute mean scores, and their standard deviations. The present results demonstrated that the pulsatile GET vocoders simulate the cochlear implant performance more accurately than the conventional sinusoid or noise vocoders.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis research was supported by NIH R01 DC15587 (F.G.Z.), National Natural Science Foundation of China (11704129 and 61771320), Guangdong Basic and Applied Basic Research Foundation Grant (2020A1515010386), and Science and Technology Program of Guangzhou (202102020944) (Q.M.).Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:University of California Irvine Institutional Review Board and Medical Ethics Committee of Shenzhen University gave ethical approval for this work.I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data produced in the present study are available upon reasonable request to the authors