PT - JOURNAL ARTICLE AU - Constantinides, Bede AU - Webster, Hermione AU - Gentry, Jessica AU - Bastable, Jasmine AU - Dunn, Laura AU - Oakley, Sarah AU - Swann, Jeremy AU - Sanderson, Nicholas AU - Fowler, Philip W AU - Ma, Geoffrey AU - Rodger, Gillian AU - Barrett, Lucinda AU - Jeffery, Katie AU - Peto, Timothy EA AU - Stoesser, Nicole AU - Street, Teresa AU - Crook, Derrick W TI - Rapid turnaround multiplex sequencing of SARS-CoV-2: comparing tiling amplicon protocol performance AID - 10.1101/2021.12.28.21268461 DP - 2022 Jan 01 TA - medRxiv PG - 2021.12.28.21268461 4099 - http://medrxiv.org/content/early/2022/01/01/2021.12.28.21268461.short 4100 - http://medrxiv.org/content/early/2022/01/01/2021.12.28.21268461.full AB - Genome sequencing is pivotal to SARS-CoV-2 surveillance, elucidating the emergence and global dissemination of acquired genetic mutations. Amplicon sequencing has proven very effective for sequencing SARS-CoV-2, but prevalent mutations disrupting primer binding sites have necessitated the revision of sequencing protocols in order to maintain performance for emerging virus lineages. We compared the performance of Oxford Nanopore Technologies (ONT) Midnight and ARTIC tiling amplicon protocols using 196 Delta lineage SARS-CoV-2 clinical specimens, and 71 mostly Omicron lineage samples with S gene target failure (SGTF), reflecting circulating lineages in the United Kingdom during December 2021. 96-plexed nanopore sequencing was used. For Delta lineage samples, ARTIC v4 recovered the greatest proportion of ≥90% complete genomes (81.1%; 159/193), followed by Midnight (71.5%; 138/193) and ARTIC v3 (34.1%; 14/41). Midnight protocol however yielded higher average genome recovery (mean 98.8%) than ARTIC v4 (98.1%) and ARTIC v3 (75.4%), resulting in less ambiguous final consensus assemblies overall. Explaining these observations were ARTIC v4’s superior genome recovery in low viral titre/high cycle threshold (Ct) samples and inferior performance in high titre/low Ct samples, where Midnight excelled. We evaluated Omicron sequencing performance using a revised Midnight primer mix alongside prototype ARTIC v4.1 primers, head-to-head with the existing commercially available Midnight and ARTIC v4 protocols. The revised protocols both improved considerably the recovery of Omicron genomes and exhibited similar overall performance to one another. Revised Midnight protocol recovered ≥90% complete genomes for 85.9% (61/71) of Omicron samples vs. 88.7% (63/71) for ARTIC v4.1. Approximate cost per sample for Midnight (£12) is lower than ARTIC (£16) while hands-on time is considerably lower for Midnight (∼7 hours) than ARTIC protocols (∼9.5 hours).Competing Interest StatementSome Midnight sequencing kits used in this study were provided free of charge by Oxford Nanopore TechnologiesFunding StatementThis study is supported by the National Institute for Health Research (NIHR) Health Protection Research Unit in Healthcare Associated Infections and Antimicrobial Resistance (NIHR200915), a partnership between the UK Health Security Agency (UKHSA) and the University of Oxford. Computation used the Oxford Biomedical Research Computing (BMRC) facility, a joint development between the Wellcome Centre for Human Genetics and the Big Data Institute supported by Health Data Research UK and the NIHR Oxford Biomedical Research Centre. The views expressed are those of the author(s) and not necessarily those of the NHS, NIHR or the UKHSA.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Sample processing and analysis was covered by ethical approval for the use of anonymised oro- or nasopharyngeal specimens from patients for the diagnosis of influenza and other respiratory pathogens, including SARS-CoV-2 (North West-Greater Manchester South Research Ethics Committee [REC], REC Ref:19/NW/0730).I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesConsensus sequences, depth information and summary tables are deposited at https://github.com/bede/sars2-seq-eval https://github.com/bede/sars2-seq-eval