PT - JOURNAL ARTICLE AU - Bangash, Mansoor N AU - Hodson, James AU - Evison, Felicity AU - Patel, Jaimin M AU - Johnston, Andrew McD AU - Gallier, Suzy AU - Sapey, Elizabeth AU - Parekh, Dhruv TI - Determining the Impact of Ethnicity on the Accuracy of Measurements of Oxygen Saturations. A Retrospective Cohort Study AID - 10.1101/2021.11.21.21266662 DP - 2021 Jan 01 TA - medRxiv PG - 2021.11.21.21266662 4099 - http://medrxiv.org/content/early/2021/11/26/2021.11.21.21266662.short 4100 - http://medrxiv.org/content/early/2021/11/26/2021.11.21.21266662.full AB - Background Pulse oximeters are routinely used in community and hospital settings worldwide as a rapid, non-invasive, and readily available bedside tool to approximate blood oxygenation. Potential racial biases in SpO2 measurements may influence the accuracy of pulse oximetry readings and impact clinical decision making. We aimed to assess whether the accuracy of oxygen saturation measured by peripheral pulse oximetry (SpO2), relative to arterial blood gas (SaO2), varies by ethnicity.Methods In this large retrospective observational cohort study covering four NHS Hospitals serving a large urban population in Birmingham, consecutive patients admitted to hospital requiring oxygen therapy were identified by electronic patient records. For each spell, the first available pair of SpO2 and SaO2 measurements taken within an interval of less than 20 minutes were identified and included in the analysis. The differences between SpO2 and SaO2 measurements, were compared across self-identified groups of ethnicities. These differences were subsequently adjusted for age, sex, bilirubin, systolic blood pressure, carboxyhaemaglobin saturations and the time interval between SpO2 and SaO2 measurements.Findings Paired O2 saturation measurements from 16818 inpatient spells between 1st January 2017 and 18th February 2021, were analysed. The cohort self-identified as being of White (81.2%), Asian (11.7%), Black (4.0%), or Other (3.2%) ethnicities. Across the cohort, SpO2 was significantly higher than SaO2 (median: 98% vs. 97%, p<0.001), with a median difference of 0.5 percentage points (pps). However, the size of this difference varied considerably with the magnitude of SaO2, with SpO2 overestimation by a median of 3.8pp for SaO2 values <90% but underestimating by a median of 0.4pp for an SaO2 of 95%. The differences between SpO2 and SaO2 were also found to vary significantly by ethnicity, with this difference being 0.8pp (95% confidence interval: 0.6-1.0) greater in those of Black vs. White ethnicity. These differences resulted in 6.1% vs. 8.7% of White vs. Black patients classified as normoxic on SpO2 who were hypoxic on the gold standard SaO2 reading (p=0.007).Interpretation Pulse oximetry tends to overestimate O2 saturation, and this is more pronounced in patients of Black ethnicity. Prospective studies are urgently warranted to assess the impact of ethnicity on the accuracy of pulse oximetry, to ensure care is optimised for all.Funding This work was supported by PIONEER, the Health Data Research UK (HDR-UK) Health Data Research Hub in acute care. HDR-UK is an initiative funded by the UK Research and Innovation, Department of Health and Social Care (England) and the devolved administrations, and leading medical research charities.Competing Interest StatementCompeting interests: All authors have completed the ICMJE uniform disclosure form at www.icmje.org/coi_disclosure.pdf and declare: DP reports funding from the NIHR and MRC. ES reports funding support from HDR-UK, MRC, Wellcome Trust, NIHR, Alpha-1-Foundation and British Lung Foundation. ES declares receiving consulting fees from Boehringer Ingleheim and support to attend scientific meetings from Astra Zeneca. MB reports funding from the UK Intensive Care SocietyFunding StatementThis work was supported by PIONEER, the Health Data Research UK (HDR-UK) Health Data Research Hub in acute care. HDR-UK is an initiative funded by the UK Research and Innovation, Department of Health and Social Care (England) and the devolved administrations, and leading medical research charities.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:This data study was supported by PIONEER, a Health Data Research Hub in Acute Care with ethical approval provided by the East Midlands Derby REC (reference: 20/EM/0158).I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesData is available upon reasonable application to the PIONEER Hub. All data access applications will be reviewed in accordance with the PIONEER ethical approvals and governance processes.