RT Journal Article SR Electronic T1 Integrity performance assessment of a Closed System Transfer Device syringe adaptor as a terminal closure for Luer-Lock syringes JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2021.11.11.21266172 DO 10.1101/2021.11.11.21266172 A1 Walker, Kate E A1 Machníková, Romana A1 Ozolina, Laima A1 Wilkinson, Alan-Shaun A1 Johnson, Andrew J A1 Bhogal, Navneet A1 Pegg, Kate YR 2021 UL http://medrxiv.org/content/early/2021/11/14/2021.11.11.21266172.abstract AB Objectives To investigate the container closure integrity of a Closed System Transfer Device syringe adaptor lock in combination with disposable Luer-Lock syringes as the terminal closure device. The UK NHS Pharmaceutical Quality Assurance committee requires syringe integrity data for final storage devices of aseptic products such as chemotherapy drugs when prepared in advance and stored prior to use as is standard practice for dose banded drugs. The assessment comprised both physical and microbial integrity testing of the combination closed system/ Luer-Lock syringes containers at syringe sizes: 1mL, 20mL, and 50mL.Methods Integrity testing was performed as described in the NHS Pharmaceutical Quality Assurance Committee Yellow Cover Document 2nd edition 2013 with Chemfort™ (Simplivia, IL) syringe adaptor lock devices as replacement for sterile blind hubs. Microbiological integrity was assessed according to Method 1 part 1.4 using Brevundimonas diminuta at 32°C for up to 14-days contact time. Physical integrity was assessed using Method 3 of the yellow cover document which is a dye intrusion method. Dye intrusion was assessed both visually and using a validated ultraviolet-visible spectrophotometer method.Results Chemfort™ syringe adaptor lock/ Luer-Lock syringe combinations were shown to be: (1) free of microbiological contamination after 14-days contact time, (2) free of dye intrusion at all syringe sizes tested (n=61 in total). The data demonstrates 100% closure integrity of the final container system when Chemfort™ syringe adaptor lock replaces the syringe hub as the terminal closure device.Conclusions Syringe adaptor lock components complied with the NHS Pharmaceutical Quality Assurance Committee Yellow Cover Document syringe integrity requirements when used as the terminal closure of Luer-Lock disposable syringes from 1mL up to 50mL. Therefore, syringe adaptor lock (Chemfort™) can be used as the terminal closure system for pre-filled syringes of chemotherapeutic drug products prepared in advance in UK NHS Pharmaceutical Technical Services.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThe work described was performed in accordance with a research grant from Simplivia Healthcare. The authors would like to acknowledge Simplivia Healthcare for the kind donation of the Chemfort medical devices which were used in the testing and for financial assistance in the form of a research grant to support the work. The authors have no conflict of interest and are all either employed directly by BSTL or sub-contracted under a collaboration agreement.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesI confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data produced in the present study are available upon reasonable request to the authors.