RT Journal Article SR Electronic T1 Localized and Whole-Room Effects of Portable Air Filtration Units on Aerosol Particle Deposition and Concentration in a Classroom Environment JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2021.08.22.21262392 DO 10.1101/2021.08.22.21262392 A1 Kong, Meng A1 Li, Linhao A1 Eilts, Stephanie M. A1 Li, Li A1 Hogan, Christopher J. A1 Pope, Zachary C. YR 2021 UL http://medrxiv.org/content/early/2021/08/30/2021.08.22.21262392.abstract AB In indoor environments with limited ventilation, recirculating portable air filtration (PAF) units may reduce COVID-19 infection risk via not only the direct aerosol route (i.e., inhalation) but also via an indirect aerosol route (i.e., contact with the surface where particles deposited). We systematically investigated the impact of PAF units in a mock classroom, as a supplement to background ventilation, on localized and whole-room surface deposition and particle concentration. Fluorescently tagged particles with a volumetric mean diameter near two micrometers were continuously introduced into the classroom environment via a breathing simulator with a prescibed inhalation-exhalation waveform. Deposition velocities were inferred on >50 horizontal and vertical surfaces throughout the classroom, while aerosol concentrations were spatially monitored via optical particle spectrometry. Results revealed a particle decay rate consistent with expectations based upon the reported clean air delivery rates of the PAF units. Additionally, the PAF units reduced peak concentrations by a factor of around 2.5 compared to the highest concentrations observed and led to a statistically significant reduction in deposition velocities for horizontal surfaces >2.5 m from the aerosol source. Our results not only confirm PAF units can reduce particle concentrations but also demonstrate that they may lead to reduced particle deposition throughout an indoor environment when properly positioned.Practical ImplicationsPortable air filtration units should be prioritized in classrooms as part of a multi-layed strategy to mitigate potentially infectious particle transmission by direct aerosol transmission via inhalation and indirect aerosol transmission via particle deposition to surfaces and later contact with said surfaces.When placing portable air filtration unit(s) within a classrom space, one should consider the airflow field within the classroom, the characteristic operational mode (heating vs. cooling) of the heating, ventilation, and air conditioning system, the predominantly occupied areas of the classroom, and interference with the regular teaching and learning activities.Competing Interest StatementDelos Living, LLC. currently markets and sells the Intellipure Compact portable air filtration unit used during the current study. The Well Living Lab was founded as a collaboration between Delos Living, LLC. and Mayo Clinic. Delos employs Drs. Zachary C. Pope and Meng Kong as well as Mr. Linhao Li but are assigned to the Well Living Lab which is a wholly-owned subsidiary of Delos. However, Delos Living, LLC. had no input on the study design, data collection, data analysis, or publication of this study. The other authors, Professor Christopher J. Hogan, Jr., Ms. Stephanie Eilts, and Dr. Li Li have no conflicts of interest to declare.Funding StatementThis study was funded by Delos Living, LLC. However, Delos Living, LLC, had no input on any part of the experimental process.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:This study does not require an IRB.All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesThe authors confirm that the data supporting the findings of this study are available within the article and its supporting information.