RT Journal Article SR Electronic T1 Premature Atrial Stimulation Accentuates Conduction Abnormalities in Cardiac Surgery Patients that Develop Postoperative Atrial Fibrillation JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2021.07.29.21261342 DO 10.1101/2021.07.29.21261342 A1 Khan, Muhammad S. A1 Lange, Matthias A1 Ranjan, Ravi A1 Sharma, Vikas A1 Glotzbach, Jason P. A1 Selzman, Craig A1 Dosdall, Derek J. YR 2021 UL http://medrxiv.org/content/early/2021/07/31/2021.07.29.21261342.abstract AB BACKGROUND postoperative atrial fibrillation (POAF) is a common cardiac surgery complication that is associated with increased complications and negative outcomes, but the association between presurgical atrial conduction abnormalities and POAF has not been investigated clinically during premature atrial S1S2 stimulation. This clinical study sought to examine whether intraoperative premature atrial stimulation reveals increased areas of slowed and/or blocked conduction in patients that develop POAF.METHODS High-density intraoperative epicardial left atrial mapping was conducted in 20 cardiac surgery patients with no prior history of atrial fibrillation (AF). In 20 patients, 6 (30%) developed POAF. A flexible-array of 240-electrodes was placed on the posterior left atrial wall in between the pulmonary veins. Activation maps were generated for sinus and premature atrial S1S2 stimulated beats. The area of conduction block (CB), conduction delay (CD) and the combination of both (CDCB) for conduction velocity <0.1, 0.1≤x<0.2 and <0.2 m/s, respectively were quantified.RESULTS For a premature atrial S2 beat with shortest cycle length captured, conduction velocity maps revealed a significantly higher area for CD (13.19±6.59 versus 6.06±4.22 mm2, p=0.028) and CDCB (17.36±8.75 versus 7.41±6.39 mm2, p=0.034), and a trend toward a larger area for CB (4.17±3.66 versus 1.34±2.86 mm2, p=0.063) in patients who developed POAF in comparison to those that remained in the sinus. Sinus and S1 paced beats did not show substantial differences in abnormal conduction areas between patients with and without POAF.CONCLUSION In comparison to sinus and S1 beats, premature atrial S2 beats accentuate conduction abnormalities in cardiac surgery patients that developed POAF.Competing Interest StatementRR is a consultant for Abbott, Medtronic, and Biosense Webster. All other authors have no relevant financial or non-financial interests to disclose.Funding StatementResearch reported in this publication was supported by National Heart, Lung, and Blood Institute of the National Institutes of Health, NIH under award: R01HL128752 (DJD), R01HL142913 (RR), a research grant from the Nora Eccles Treadwell Foundation (DJD) and American Heart Association, AHA under award: 9POST34450115 (MSK). The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH and AHA.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:The study protocol was approved by the Institutional Review Board of the University of Utah Health (IRB_00101187). All experiments were performed in accordance with relevant guidelines and regulations as approved, and the written informed consent was obtained from all 22 patients.All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesThe datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.