RT Journal Article SR Electronic T1 A novel strategy for the detection of SARS-CoV-2 variants based on multiplex PCR-MALDI-TOF MS JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2021.06.08.21258523 DO 10.1101/2021.06.08.21258523 A1 Zhao, Fei A1 Zhang, Jianzhong A1 Wang, Xuemei A1 Hou, Xuexin A1 Qin, Tian A1 Meng, Fanliang A1 Xu, Xiaona A1 Li, Tianyi A1 Zhou, Haijian A1 Kan, Biao A1 Lu, Jinxing A1 Xiao, Di YR 2021 UL http://medrxiv.org/content/early/2021/06/12/2021.06.08.21258523.abstract AB Background The second wave of coronavirus disease 2019 (COVID-19) has been incessantly causing catastrophe worldwide, and the emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants causes further uncertainty regarding epidemic risk. Here, a novel strategy for the detection of SARS-CoV-2 variants using multiplex PCR coupled with MALDI-TOF MS was developed.Methods Plasmids carrying gene sequences containing 9 mutation types in 7 mutated sites (HV6970del, N501Y, K417N, P681H, D614G, E484K, L452R, E484Q and P681R) in the receptor-binding domain of the spike protein of SARS-CoV-2 variants were synthesized. Using the nucleic acid sequence of SARS-CoV-2 nonvariant and a synthetic SARS-CoV-2-variant-carrying plasmid, a MALDI-TOF MS method based on the single-base mass probe extension of multiplex PCR amplification products was established to detect the above nine mutation types. The detection limit of this method was determined via the concentration gradient method. Twenty-one respiratory tract pathogens (9 bacteria, 11 respiratory viruses) and pharyngeal swab nucleic acid samples from healthy people were selected for specific validation. Sixteen samples from COVID-19 patients were used to verify the accuracy of this method.Results The 9 mutation types could be detected simultaneously by triple PCR amplification coupled with MALDI-TOF MS. SARS-CoV-2 and all six variants (B.1.1.7, B.1.351, B.1.429, B.1.526, P.1 and B.1.617) could be identified. The detection limit for all 9 sites was 1.5×103 copies. The specificity of this method was 100%, and the accuracy of real-time PCR CT values less than 30 among positive samples was 100%. This method is open and extensible, and can be used in a high-throughput manner, easily allowing the addition of new mutation sites as needed to identify and track new SARS-CoV-2 variants as they emerge.Conclusions Multiplex PCR-MALDI-TOF MS provides a new detection option with practical application value for SARS-CoV-2 and its variant infection.Key point An all-in-one SARS-CoV-2 variant identification method based on a multiplex PCR-MALDI-TOF MS system was developed. All of the SARS-CoV-2 variants can be identified based on 9 types of 7 mutated sites of RBD of spike protein using this method.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis work was supported by The Major Infectious Diseases AIDS and Viral Hepatitis Prevention and Control Technology Major Projects (Grant No. 2018ZX10712001-006012).Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Ethical Committee of National institute for communicable disease control and prevention China CDCAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll the data in the manuscript met the specifications.