PT - JOURNAL ARTICLE AU - Parhizkar, Hooman AU - Van Den Wymelenberg, Kevin AU - Haas, Charles AU - Corsi, Richard TI - A quantitative risk estimation platform for indoor aerosol transmission of COVID-19 AID - 10.1101/2021.03.05.21252990 DP - 2021 Jan 01 TA - medRxiv PG - 2021.03.05.21252990 4099 - http://medrxiv.org/content/early/2021/03/09/2021.03.05.21252990.short 4100 - http://medrxiv.org/content/early/2021/03/09/2021.03.05.21252990.full AB - Aerosol transmission has played a significant role in the transmission of COVID-19 disease worldwide. We developed a COVID-19 aerosol transmission risk estimation platform to better understand how key parameters associated with indoor spaces and infector emissions affect inhaled deposited dose of aerosol particles that convey the SARS-CoV-2 virus. The model calculates the concentration of size-resolved, virus-laden aerosol particles in well-mixed indoor air challenged by emissions from an index case(s). The model uses a mechanistic approach, accounting for particle emission dynamics, particle deposition to indoor surfaces, ventilation rate, and single-zone filtration. The novelty of this model relates to the concept of “inhaled & deposited dose” in the respiratory system of receptors linked to a dose-response curve for human coronavirus HCoV-229E. We estimated the volume of inhaled & deposited dose of particles in the 0.5 to 4 μm range expressed in picoliters (pL) in a well-documented COVID-19 outbreak in restaurant X in Guangzhou China. We anchored the attack rate with the dose-response curve of HCoV-229E which provides a preliminary estimate of the average SARS-CoV-2 dose per person, expressed in plaque forming units (PFUs). For a reasonable emission scenario, we estimate approximately three PFU per pL deposited, yielding roughly 10 PFUs deposited in the respiratory system of those infected in Restaurant X. To explore the platform’s utility, we tested the model with four COVID-19 outbreaks. The risk estimates from the model fit reasonably well with the reported number of confirmed cases given available metadata from the outbreaks and uncertainties associated with model assumptions.Practical Implications The model described in this paper is more mechanistic in nature than standard probabilistic models that fail to account for particle deposition to indoor materials, filtration, and deposition of particles in the respiratory system of receptors. As such, it provides added insights into how building-related factors affect relative infection risk associated with inhaled deposited dose. An online version of this mechanistic aerosol risk estimation platform is available at Safeairspaces.com. Importantly, the modular nature of this approach allows for easy updates when new information is available regarding dose-response relationships for SARS-CoV-2 or its variants.Competing Interest StatementThe authors have declared no competing interest.Funding StatementNo external funding was received.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:This research did not include human subjects.All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesThis is a model for infectious disease transmission risk in indoor environments. All data used in this study were publicly available. https://safeairspaces.com/