PT - JOURNAL ARTICLE AU - Torres, Ignacio AU - Poujois, Sandrine AU - Albert, Eliseo AU - Colomina, Javier AU - Navarro, David TI - Real-life evaluation of a rapid antigen test (Panbio™ COVID-19 Ag Rapid Test Device) for SARS-CoV-2 detection in asymptomatic close contacts of COVID-19 patients AID - 10.1101/2020.12.01.20241562 DP - 2020 Jan 01 TA - medRxiv PG - 2020.12.01.20241562 4099 - http://medrxiv.org/content/early/2020/12/02/2020.12.01.20241562.short 4100 - http://medrxiv.org/content/early/2020/12/02/2020.12.01.20241562.full AB - Objectives There is limited information on the performance of rapid antigen detection (RAD) tests to identify SARS-CoV-2-infected asymptomatic individuals. In this field study, we evaluated the Panbio™ COVID-19 Ag Rapid Test Device (Abbott Diagnostics, Jena, Germany) for the purpose.Methods A total of 634 individuals (355 female; median age, 37 years; range, 9-87) were enrolled. Household (n=338) contacts were tested at a median of 2 days (range, 1-7) after diagnosis of the index case and non-household contacts (n=296) at a median of 6 days (range, 1-7) after exposure. RAD testing was carried out at the point of care. The RT-PCR test used was the TaqPath COVID-19 Combo Kit (Thermo Fisher Scientific, Massachusetts, USA).Results In total, 79 individuals (12.4%) tested positive by RT-PCR, of whom 38 (48.1%) yielded positive RAD results. The overall sensitivity and specificity of the RAD test was 48.1% (95% CI: 37.4-58.9) and 100% (95% CI: 99.3-100), respectively. Sensitivity was higher in household (50.8%; 95% CI: 38.9-62.5) than in non-household (35.7%; 95% CI:16.3-61.2%) contacts. Individuals testing positive by RAD test were more likely (P<0.001) to become symptomatic than their negative counterparts.Conclusion The Panbio test displays low sensitivity in asymptomatic close contacts of COVID-19 patients, particularly in non-household contacts. Nonetheless, establishing the optimal timing for upper respiratory tract collection in this group seems imperative to pinpoint test sensitivity.Competing Interest StatementThe authors have declared no competing interest.Funding StatementThis work received no public or private funds.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Approved by the ethics committee of INCLIVAAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesThe authors confirm that the data supporting the findings of this study are available within the article [and/or] its supplementary materials.