Abstract
Background Coronavirus disease 2019 (COVID-19) has surprised the world since the beginning of 2020, and the rapid growth of COVID-19 is beyond the capability of doctors and hospitals that could deal in many areas. The chest computed tomography (CT) could be served as an effective tool in detection of COVID-19. It is valuable to develop automatic detection of COVID-19.
Materials and Methods The collected dataset consisted of 1042 chest CT images (including 521 COVID-19, 397 healthy, 76 bacterial pneumonia and 48 SARS) obtained by exhaustively searching available data on the Internet. Then, these data are divided into three sets, referred to training set, validation set and testing set. Sixteen data augmentation operations are designed to enrich the training set in deep learning training phase. Multiple experiments were conducted to analyze the performance of the model in the detection of COVID-19 both in case of no noisy labels and noisy labels. The performance was assessed by the area under the receiver operating characteristic (AUC), sensitivity, specificity and accuracy.
Results The data augmentation operations on the training set are effective for improvement of the model performance. The area under the receiver operating characteristic curve is 0.9689 with (95% CI: 0.9308, 1) in case of no noisy labels for the classification of COVID-19 from heathy subject, while the per-exam sensitivity, specificity and accuracy for detecting COVID-19 in the independent testing set are 90.52%, 91.58% and 91.21%, respectively. In the classification of COVID-19 from other hybrid cases, the average AUC of the proposed model is 0.9222 with (95%CI: 0.8418, 1) if there are no noisy labels. The model is also robust when part of the training samples is marked incorrectly. The average AUC is 92.23% in the case of noisy labels of 10% in the training set.
Conclusion A deep learning model with insufficient samples can be developed by using data augmentation in assisting medical workers in making quick and correct diagnosis of COVID-19.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This work was supported by NSFC (No.61772234)
Author Declarations
All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
The CT images are obtained from the internet, including the two proposed papers and a regular medical website.
https://arxiv.org/abs/2003.13865