Abstract
Blood pressure gradient (ΔP) across an aortic coarctation (CoA) is an important measurement to diagnose CoA severity and guide treatment. While invasive cardiac catheterization is the clinical gold-standard for measuring ΔP, it requires anesthesia and does not capture the effects of daily activity or exercise, potentially underestimating the disease’s functional burden. This study aimed to identify patients with functionally significant CoA by evaluating exercise-induced ΔP using a hybrid mock circulatory loop (HMCL). Patient-specific aorta geometries (N=5) of patients with CoA were generated from 4D-Flow magnetic resonance imaging (MRI) scans, then 3D-printed to create compliant aortic phantoms. The phantoms were incorporated into an HMCL with flow and pressure waveforms tuned to patient-specific rest and exercise states. Matched fluid-structure interaction (FSI) simulations were performed using SimVascular for comparison. Results showed that mean ΔP increased non-linearly with cardiac output (CO), with trends differing between patients. HMCL and FSI simulations exhibited excellent agreement in trends of ΔP change with CO, with minimal error of 1.6 ± 1.1 mmHg. This study emphasizes the need for assessing exercise CoA hemodynamics beyond resting ΔP measurements. Overall, HMCLs and FSI simulations enable assessment of patient-specific hemodynamic response to exercise unattainable in clinical practice, thereby facilitating a comprehensive non-invasive assessment of CoA severity. Further, the excellent agreement between HMCL and FSI results indicates that our validated FSI approach can be used independently to assess exercise CoA hemodynamics hereafter, eliminating the need for repeated complex HMCL experiments.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This work was funded by Digital Futures at KTH, VINNOVA (2022-00849), the Digitalisation platform at KTH, Stanford's Maternal and Child Health Research Institute, and the American Scandinavian Foundation.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
IRB of Stanford University gave ethical approval for this work.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Data Availability
All simulation data from this work will be available on the Vascular Model Repository (vascularmodel.org)