Abstract
Stress can adversely impact health, leading to issues like high blood pressure, heart diseases, and a compromised immune system. Consequently, using wearable devices to monitor stress is essential for prompt intervention and effective management. This study investigates the efficacy of wearable devices in the early detection of psychological stress, employing both binary and five-class classification models. Significant correlations were observed between stress levels and physiological signals, including Electrocardiogram (ECG), Electrodermal Activity (EDA), and Respiration (RESP), establishing these modalities as reliable biomarkers for stress detection. Utilizing the publicly available Wearable Stress and Affect Detection (WESAD) dataset, we employed two ensemble methods, Majority Voting (MV) and Weighted Averaging (WA), to integrate these signals, achieving maximum accuracies of 99.96% for binary classification and 99.59% for five-class classification. This integration significantly enhances the accuracy and robustness of the stress detection system. Furthermore, ten different classifiers were evaluated, and hyperparameter optimization and K-fold cross-validation ranging from 3-fold to 10-fold were applied. Both time-domain and frequency-domain features were examined separately. A review of commercially available wearable devices supporting these modalities was also conducted, resulting in recommendations for optimal configurations for practical applications. Our findings highlight the potential of multimodal wearable devices in advancing the early detection and continuous monitoring of psychological stress, with significant implications for future research and the development of improved stress detection systems.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study did not receive any funding
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
https://ubicomp.eti.uni-siegen.de/home/datasets/icmi18/
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Appendix: List of Abbreviations
- AB
- AdaBoost
- ACC
- Accuracy
- ACCE
- Three-Axis Acceleration
- AI
- Artificial Intelligence
- Avg
- Average
- BAG
- Bagging
- BVP
- Blood Volume Pulse
- cGAN
- Conditional Generative Adversarial Network
- CNN
- Convolutional Neural Network
- DL
- Deep Learning
- DNN
- Deep Neural Network
- DT
- Decision Tree
- ECG
- Electrocardiogram
- EDA
- Electrodermal Activity
- ET
- Extra Trees
- F1
- F1 Score
- FCN
- Fully Convolutional Network
- FFT
- Fast Fourier Transform
- GAN
- Generative Adversarial Network
- GCN
- Graph Convolutional Networks
- GSR
- Galvanic Skin Response
- HR
- Heart Rate
- HRV
- Heart Rate Variability
- IMU
- Inertial Measurement Unit
- kNN
- k-Nearest Neighbors
- K-CV
- K-fold Cross-Validation
- LDA
- Linear Discriminant Analysis
- LOSO
- Leave-One-Subject-Out
- LR
- Logistic Regression
- LSTM
- Long Short-Term Memory
- ML
- Machine Learning
- MLP
- Multi-Layer Perceptron
- MMTM
- Multimodal Transfer Module
- MV
- Majority Voting
- P
- Precision
- PANAS
- Positive and Negative Affect Schedule Questionnaire
- PPG
- Photoplethysmography
- PRV
- Pulse Rate Variability
- PSD
- Power Spectral Density
- QDA
- Quadratic Discriminant Analysis
- R
- Recall
- RESP
- Respiration
- RF
- Random Forest
- ROC
- Receiver Operating Characteristic
- SFM
- Select From Model
- SKT
- Skin Temperature
- SVM
- Support Vector Machine
- TEMP
- Body Temperature
- TSST
- Trier Social Stress Test
- WA
- Weighted Average
- WESAD
- Wearable Stress and Affect Detection Dataset
- XGB
- Extreme Gradient Boosting
The Chan Zuckerberg Initiative, Cold Spring Harbor Laboratory, the Sergey Brin Family Foundation, California Institute of Technology, Centre National de la Recherche Scientifique, Fred Hutchinson Cancer Center, Imperial College London, Massachusetts Institute of Technology, Stanford University, University of Washington, and Vrije Universiteit Amsterdam.