Abstract
Computer-aided systems can help the ophthalmologists in early detection of most of ocular abnormalities using retinal OCT images. The need for more accurate diagnosis increases the need for modifications and innovations to current algorithms. In this paper, we investigate the effect of different X-lets on the classification of OCT B-scans of a dataset with one normal class and two abnormal classes. Different transforms of each B-scan have been fed to the designed 2D-Convolutional-Neural-Network (2D-CNN) to extract the best-suited features. We compare the performance of them with MSVM and MLP classifiers. Comparison with the accuracy of normal and abnormal classes reveals substantially better results for normal cases using 2D-Discrete-Wavelet-Transform (2D-DWT), since the structure of most normal B-scans follows a pattern with zero-degree lines, while for abnormalities with circles appearing in the retinal structure (due to the accumulation of fluid), the circlet transform performs much better. Therefore, we combine these two X-lets and propose a new transform named CircWave which uses all sub-bands of both transformations in the form of a multi-channel-matrix, with the aim to increase the classification accuracy of normal and abnormal cases, simultaneously. We show that the classification results obtained based on CircWave transform outperform those based on the original images and each individual transform. Furthermore, the Grad-CAM class activation visualization for B-scans reconstructed from half of the CircWave sub-bands indicates a greater focus on appearing circles in abnormal cases and straight lines in normal cases at the same time, while for original B-scans the focus of the heat-map is on some irrelevant regions. To investigate the generalizability of our proposed method we have applied it also to another dataset. Using the CircWave transform, we have obtained an accuracy of 94.5% and 90% for the first and second dataset, respectively, while these values were 88% and 83% using the original images. The proposed CNN based on CircWave provides not only superior evaluation parameter values but also better interpretable results with more focus on features that are important for ophthalmologists.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This study did not receive any funding
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
the study used ONLY openly available human data that were originally located at: https://misp.mui.ac.ir/en/dataset-oct-classification-50-normal-48-amd-50-dme-0 and OCT Basel Data | Medical Image and Signal Processing Research Center
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
The Chan Zuckerberg Initiative, Cold Spring Harbor Laboratory, the Sergey Brin Family Foundation, California Institute of Technology, Centre National de la Recherche Scientifique, Fred Hutchinson Cancer Center, Imperial College London, Massachusetts Institute of Technology, Stanford University, University of Washington, and Vrije Universiteit Amsterdam.