Abstract
Rapid diagnosis of pathogens is the cornerstone of appropriate therapy and is also a great challenge to be overcome. Although NGS and some other PCR-based pathogen detection methods were applied to improve the speed and accuracy of clinical diagnosis, it was still a long way from the clinical needs of rapid and accurate diagnostic therapy in the intensive care unit (ICU). In this study, we aimed at developing a new rapid diagnostic tool, Species-Specific Bacterial Detector (SSBD), to evaluate the existence and quantification of 10 most usual pathogenic bacteria in ICU in 4 hours. Briefly, the species-specific genome fragments of each bacterium were identified by our algorithm using 1791 microbe genomes from 232 species and then used to combine with CRISPR/Cas12 to establish diagnosis tools. Based on the tests of 77 samples, SSBD demonstrated 100% sensitivity and 87% specificity compared with conventional culture test (CCT). Later on, an interventional random-grouped study was applied to evaluate the clinical benefits of SSBD. Briefly, SSBD demonstrated more accurate and faster diagnosis results and led to earlier antibiotics adjustment than CCT. Based on the results acquired by SSBD, cultivation results could deviate from the real pathogenic situation with polymicrobial infections. In addition, nosocomial infections were found widely in ICU, which should deserve more attention.
Competing Interest Statement
The authors have declared no competing interest.
Clinical Trial
NCT04178382
Funding Statement
This study was funded by National Natural Science Foundation of China. The National Key Scientific Instrument and Equipment Development Project. Project number: 81927808.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Our study acquired the ethics approval (2019-197-01) from the ethics committee of Nanjing Drum Tower Hospital Affiliated to Nanjing University Medical School in July 2019
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
↵# These authors share first author
Data Availability
All data produced in the present work are contained in the manuscript.