Evaluation of a novel, rapid antigen detection test for the diagnosis of SARS-CoV-2 =================================================================================== * Rainer Thell * Verena Kallab * Wolfgang Weinhappel * Wolfgang Mueckstein * Lukas Heschl * Martina Heschl * Stefan Korsatko * Franz Toedling * Amelie Blaschke * Theresa Herzog * Anna Klicpera * Clara Koeller * Moritz Haugk * Anna Kreil * Alexander Spiel * Philipp Kreuzer * Robert Krause * Christian Sebesta * Stefan Winkler * Brenda Laky * Marton Szell ## ABSTRACT **Background** Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causing coronavirus disease 2019 (COVID-19) is currently finally determined in laboratory settings by real-time reverse-transcription polymerase-chain-reaction (rt-PCR). However, simple testing with immediately available results are crucial to gain control over COVID-19. The aim was to evaluate such a point-of-care antigen rapid test (AG-rt) device in its performance compared to laboratory-based rt-PCR testing in COVID-19 suspected, symptomatic patients. **Methods** For this prospective study, two specimens each of 541 symptomatic female (54.7%) and male (45.3%) patients aged between 18 and 95 years tested at five emergency departments (ED, n=296) and four primary healthcare centres (PHC, n=245), were compared, using AG-rt (positive/negative/invalid) and rt-PCR (positive/negative and cycle threshold, Ct) to diagnose SARS-CoV-2. Diagnostic accuracy, sensitivity, specificity, positive predictive values (PPV), negative predictive value (NPV), and likelihood ratios (LR+/-) of the AG-rt were assessed. **Results** Differences between ED and PHC were detected regarding gender, age, symptoms, disease prevalence, and diagnostic performance. Overall, 174 (32.2%) were tested positive on AG-rt and 213 (39.4%) on rt-PCR. AG correctly classified 91.7% of all rt-PCR positive cases with a sensitivity of 80.3%, specificity of 99.1%, PPV of 98.3, NPV of 88.6%, LR(+) of 87.8, and LR(-) of 0.20. The highest sensitivities and specificities of AG-rt were detected in PHC (sensitivity: 84.4%, specificity: 100.0%), when using Ct of 30 as cut-off (sensitivity: 92.5%, specificity: 97.8%), and when symptom onset was within the first three days (sensitivity: 82.9%, specificity: 99.6%). **Conclusions** The highest sensitivity was detected with a high viral load. Our findings suggest that AG-rt are comparable to rt-PCR to diagnose SARS-CoV-2 in COVID-19 suspected symptomatic patients presenting both at emergency departments and primary health care centres. **SUMMARY** The rapid SARS-Cov-2 antigen test (SARS-CoV-2 Rapid Antigen Test (Roche Diagnostics), was compared in symptomatic patients with PCR testing both in emergency departments and primary health care centres. It showed an overall sensitivity of 80.3% and specificity of 99.1%; these were higher with lower PCR cycle threshold numbers and with a shorter onset of symptoms. Keywords * COVID-19 * SARS-CoV-2 * rapid COVID-19 test * point-of-care test ## INTRODUCTION Conventional diagnostic steps for infection with SARS-CoV-19 were epidemiological contact history, clinical impression, chest radiography, standard blood laboratory, and antigen detection by means of real-time polymerase chain reaction (rt-PCR). PCR remains the gold standard test for detection of SARS-CoV-2 infection.[1] As SARS-CoV-2 is being fought, testing not just of patients with suspected infection, but as well healthy individuals, takes places with rapid antigen test lateral flow devices.[2, 3] The way of handling is advantageous to PCR testing, as there is neither a need for laboratory staff nor for a laboratory environment, and the lateral flow device is rapid in application and timely superior to the PCR procedure. It soon became apparent that in this pandemic the available capacities for PCR testing were by far from sufficient, and a feverish search for alternative and simpler detection methods began. Testing that takes a certain time can make up for significant additional efforts of organisation of patients in hospitals; and far beyond health systems, delay of testing effects societies as a whole. This regards nearly all spheres of life. Furthermore, the ideal test system is reliable, fast, easy to use, and affordable. Besides PCR-testing, detection of antibodies against SARS-CoV-2 can play a role as well. Serology is generally available, however, serology seems only interpretable with the knowledge of patient’s history and clinical appearance. IgA and IgM seem to quickly fade within 10 to 15 days, fade and thus, are not always be detectable, as opposed to IgG.[4-6] However, antigen tests tend to better detect SARS-CoV-2, the more virus load the nasopharyngeal mucus contains.[7, 8] In a meta-analysis by Dinnes et al.,[9] five trials compared rt-PCR with 943 antigen tests were pooled. The average sensitivity was 56.2% (95% CI 29.5% to 79.8%), and the average specificity was 99.5% (95% CI 98.1% to 99.9%). More promising results were reported by Porte et al., who tested 82 rt-PCR-positive samples with another rapid antigen test and found a sensitivity of 93.9%.[10] The purpose of this study was to assess the performance of a novel CE-marked *in vitro* diagnostics (IVD) assay, the SARS-CoV-2 Rapid Antigen Test (Roche Diagnostics), for the detection of SARS-CoV-2 antigen. According to the manufacturer’s manual [11], the antigen test shows 96.5% (95% CI 91.3% to 99.0%) of sensitivity and 99.7% (95% CI 98.2 to 99.9%) of specificity. ## MATERIAL AND METHODS ### Patients Patients were recruited consecutively between October 30, 2020 and December 13, 2020 at five emergency departments and four primary healthcare centres in Austria. The study was approved by four provincial ethics commissions (EK20-249-1020, GS1-EK-3/182-2020, 33-064 ex 20/21, ABT08GP-15681/2020-18). Signed informed consent was obtained from all participants. 591 symptomatic adults (≥18 years) were included, who were willing to undergo sampling twice. Inclusion criteria were cough, fever, ageusia/anosmia, shortness of breath and sore throat. A total of 49 (8.3%) patients were excluded for the following reasons: asymptomatic (n=12), children (<18years, n=10), missing rt-PCR and/or AG-rt data (n=8), unknown symptoms (n=13), and symptom onset more than two weeks prior to testing (n=6). ### Procedure Two swabs per patient were taken by experienced medical staff. The first probe was analysed using the point-of-care device (SARS-CoV-2 Rapid Antigen Test (Roche Diagnostics). Outcome was recorded 15 minutes after sampling as positive, negative, or invalid. Only one case (1/542=0.2%), a 31 year old male patient with a sore throat two days prior testing and a negative rt-PCR, showed an invalid AG-rt reading, which was not included in analysis. All rt-PCR analyses using the second probe of each patient was conducted in hospital’s laboratories or in other special laboratories. Rt-PCR results were collected as quantitative (Ct) and qualitative (positive or negative) parameters. Ct was reported in 202 of 213 cases. ### Statistical Analysis Descriptive statistics was used to describe the characteristics of patients. The distribution of the data was approximated by visual inspection of the histograms and the Kolmogorov Smirnov tests. Normally distributed data were calculated as mean value with standard deviation (SD), otherwise as median and range. Continuous variables were compared between two groups with independent t-tests (parametric) or Mann-Whitney U-tests (non-parametric). Chi-square or Fisher’s exact tests were applied to describe the relationship between proportions of categorical variables. Correlations between the continuous parameters were performed using Spearman’s rho. Percentage accuracy in classification, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. Positive (+) and negative (-) likelihood ratios (LR) were calculated using sensitivity and specificity. The larger LR(+), the greater the likelihood to be SARS-CoV-2 positive; and similarly, the smaller the LR(-), the lesser the likelihood to be SARS-CoV-2 positive. All values are presented with their 95% confidence interval (95% CI). Statistical significance was set at a p-value of <0.05 (two-sided). All data were analysed with SPSS software (IMP Statistics Version 25; SPSS Inc, Chicago, IL) and MedCalc Statistical Software version 19.6.4 (MedCalc Software bv, Ostend, Belgium; [https://www.medcalc.org](https://www.medcalc.org); 2020). ## RESULTS Included in this prospective diagnostic study were 541 symptomatic patients of five ED (n=296) and four PHC (n=245), who were tested for SARS-CoV-2 using AG-rt and rt-PCR. The average age of the consecutively tested patients including 54.7% females and 45.3% males was 49.1±19.7years (range, 18-95years). A comparison between demographic characteristics between patients tested at ED and PHC showed significant differences regarding gender, age, and some symptoms (Table 1). The main symptom for patients presenting in ED was fever, while more than 60% of patients at a PHC reported to have a sore throat as most common symptom. View this table: [Table 1.](http://medrxiv.org/content/early/2021/04/22/2021.04.22.21255637/T1) Table 1. Comparison of demographic characteristics between emergency departments (ED) and primary healthcare centres (PHC). Overall, 174 (32.2%) were tested positive on AG-rt and 213 (39.4%) on rt-PCR (Figure 1). AG correctly classified 91.7% [95%CI 89.0-93.9] of all rt-PCR positive cases with a sensitivity of 80.3% [95%CI 74.3-85.4], specificity of 99.1% [95%CI 97.4-99.8], PPV of 98.3 [95%CI 94.7-99.4], NPV of 88.6% [95%CI 85.5-91.0], LR(+) of 87.8 [28.4-271.3], and LR(-) 0.20 [0.15-0.26]. ![Fig. 1](http://medrxiv.org/https://www.medrxiv.org/content/medrxiv/early/2021/04/22/2021.04.22.21255637/F1.medium.gif) [Fig. 1](http://medrxiv.org/content/early/2021/04/22/2021.04.22.21255637/F1) Fig. 1 Overall testing outcome There were only three of 541 patients (0.6%) including two female aged 87 and 57 years and one 59-year old male with false positive AG-rt results. All three patients presented within five days of first symptoms’ onset with fever and cough and one additionally with dyspnoea. The false negative tested patients (7.8%; ED: 30 and PHC: 12) included 50% females with an average age of 53.0±17.2 years, the following symptoms: fever (n=29); cough (n=27); sore throat (n=12); dyspnoea (n=12); and dysgeusia/anosmia (n= 5) with a median symptom onset of 3 (range, 0-14 days), and an average Ct of 31.2±3.9. Sensitivity and specificity were similar regarding gender (female: 81.1% and 99.0%; male: 79.4% and 99.3%) and symptoms (fever: 79.0% and 97.6%; cough: 78.2% and 97.9%; dyspnoea: 79.0% and 98.8%; sore throat: 80.0% and 100.0%). Prevalence of the disease (positive rt-PCR test) was 36.8% in female and 42.7% in male patients; in patients aged 18 to 45 years, 46 to 65 years, and older than 65 years, the prevalence was 33.9%, 45.7%, and 42.1%, respectively (Supplement Table S1). Diagnostic performance of the AG-rt at ED and PHC are presented in Table 2. Interestingly, sensitivity was lower and there were more than twice false negatives in ED compared to PHC. View this table: [Table 2](http://medrxiv.org/content/early/2021/04/22/2021.04.22.21255637/T2) Table 2 Diagnostic performance of the antigen rapid test (AG-rt) at emergency departments (ED) and primary healthcare centres (PHC). Sensitivities between ED and PHC regarding days of symptom onset are presented in Figure 2. ![Figure 2](http://medrxiv.org/https://www.medrxiv.org/content/medrxiv/early/2021/04/22/2021.04.22.21255637/F2.medium.gif) [Figure 2](http://medrxiv.org/content/early/2021/04/22/2021.04.22.21255637/F2) Figure 2 Sensitivities (in % with 95% confidence interval in parenthesis) between ED and PHC regarding days of symptom onset. The majority of patients (72.6%) was tested within the first three days after symptom onset. Symptom onset within 3 days and between 4 and 7 days showed a sensitivity above 80%, while onset of symptoms between 8 and 14 days was associated with a far less sensitivity. However, days of onset did not correlate with Ct (Spearman’s rho=0.109; p=0.124). Details regarding diagnostic performance of the AG-rt according symptom onset are presented in Table 3. View this table: [Table 3](http://medrxiv.org/content/early/2021/04/22/2021.04.22.21255637/T3) Table 3 Diagnostic performance of the antigen rapid test (AG-rt) according symptom(s) onset. Sensitivities between ED and PHC regarding rt-PCR cut offs at 20, 25, 30, and 40 are presented in Figure 3. ![Figure 3](http://medrxiv.org/https://www.medrxiv.org/content/medrxiv/early/2021/04/22/2021.04.22.21255637/F3.medium.gif) [Figure 3](http://medrxiv.org/content/early/2021/04/22/2021.04.22.21255637/F3) Figure 3 Sensitivities (in % with 95% confidence interval in parenthesis) between ED and PHC regarding rt-PCR cut offs. Diagnostic performance of the AG-rt with rt-PCR cut-offs defined as positive (Ct = 1-39) and negative (Ct > 40), and at Ct values of 30, 25, and 20 are presented in Table 4. The highest sensitivity and specificity was detected when using Ct of 30 as cut-off. View this table: [Table 4](http://medrxiv.org/content/early/2021/04/22/2021.04.22.21255637/T4) Table 4 Diagnostic performance of the antigen rapid test (AG-rt) according to various cut-offs. Furthermore, significant lower Ct values were detected between TP (n=165; 22.2±4.2) and FN (n=37; 31.2±3.9; p<0.001; Figure 4). ![Figure 4](http://medrxiv.org/https://www.medrxiv.org/content/medrxiv/early/2021/04/22/2021.04.22.21255637/F4.medium.gif) [Figure 4](http://medrxiv.org/content/early/2021/04/22/2021.04.22.21255637/F4) Figure 4 Boxplot showing cycle threshold (Ct) values of true positive (n=165) and false negative (n=37). ## DISCUSSION Rt-PCR testing is the gold-standard procedure for SARS-CoV-2 infection. As its results are often not rapidly or timely available for every patient, the use of rt-PCR all too often is not adequate neither in emergency departments nor in general practitioner’s settings. Patient’s flows are crucial in the management of the disease, and so is the diagnostic flow in medical institutions such as emergency departments or primary health care centres. We found the SARS-CoV-2 Rapid Antigen Test (Roche Diagnostics) to produce an overall sensitivity of 80.3% and specificity of 99.1% compared with rt-PCR, both in emergency departments and primary health care centres. From symptom onset days 0 to 7, the sensitivity was much better with 82.2%, whereas it reached 62.5% with disease onset from days 8 to 14. Sensitivities were higher with lower PCR cycle threshold numbers. Our results differ from the numbers claimed by the manufacturer, who reported a sensitivity of 96.5% and a specificity of 99.7%, who might have used specimens displaying higher viral loads.[11] Sensitivities of antigen assays in previously published trials including a meta-analysis showed a wide range from 45% to 86%.[9, 10, 12-14] Direct comparison exposes varieties in test systems, onset of disease, performance of the procedure, presence of symptoms, testing institutions, and others. Notably, in our trial results including sensitivities and specificities differed between ED and PHC. We did not find a conclusive explanation for this fact; staffs and their respective training did not differ in any of the centres substantially. Only in few patients (0.6%) a false positive result was detected with the IVD compared to PCR testing. The implication of this number however, is that those patients obviously apparently are to be sequestered into quarantine jointly with patients with true positive results, as long as PCR test results are pending. This requires a careful epidemiological reflection, when mass testing is performed. The rate of false negative patients remained under 10%. None of these patients (n=37) had a Ct under 22; in 4 patients a Ct of 23 to 25, and in a further 8 patients a Ct of 27 to 30 was detected; all other patients (n=25) had a Ct above 30. This underlines the correlation of a virus detection by means of the device and the viral load. One of the limitations is the sole inclusion of symptomatic cases and not asymptomatic persons. Actually, the purpose of the device under investigation is indeed the testing of symptomatic persons with a suspected SARS-CoV-2 infection, which corresponds to the approval of the device. No severity of symptoms and progress was considered for our trial. Additionally, despite being considered as the gold standard, PCR testing is not 100% accurate and test quality crucially depends on the quality of manual sampling of specimen.[15] ## CONCLUSION This prospective study demonstrated a performance of the SARS-CoV-2 Rapid Antigen Test (Roche Diagnostics) with an overall sensitivity of 80.3% compared to rt-PCR, which, in case of a negative result, needs to be interpreted together with the duration of the disease at the time of testing, the viral load, and likely the diligence of the generation of the specimen. ## Data Availability All data stored at Klinik Donaustadt Vienna, Emergency Department and open for review anytime. ## FUNDING Roche diagnostics provided the SARS-CoV-2 Rapid Antigen Test (Roche Diagnostics). All authors declare that they have no conflict of interest. Our group received funding for this research project from Roche Diagnostics. * Received April 22, 2021. * Revision received April 22, 2021. * Accepted April 22, 2021. * © 2021, Posted by Cold Spring Harbor Laboratory This pre-print is available under a Creative Commons License (Attribution-NonCommercial 4.0 International), CC BY-NC 4.0, as described at [http://creativecommons.org/licenses/by-nc/4.0/](http://creativecommons.org/licenses/by-nc/4.0/) ## REFERENCES 1. 1.Wang Y, Kang H, Liu X, Tong Z. Combination of RT-qPCR testing and clinical features for diagnosis of COVID-19 facilitates management of SARS-CoV-2 outbreak. J Med Virol 2020; 92(6): 538–9. 2. 2.CDC. Centers for Disease Control and Prevention. ARS-CoV-2 Testing Strategy: Considerations for Non-Healthcare Workplaces. 21 October 2020. 3. 3.ECDPC. European Centre for Disease Prevention and Control. COVID-19 testing strategies and objectives. 15 September 2020. 4. 4.Okba NMA, Muller MA, Li W, et al. Severe Acute Respiratory Syndrome Coronavirus 2-Specific Antibody Responses in Coronavirus Disease Patients. Emerg Infect Dis 2020; 26(7): 1478–88. [PubMed](http://medrxiv.org/lookup/external-ref?access_num=http://www.n&link_type=MED&atom=%2Fmedrxiv%2Fearly%2F2021%2F04%2F22%2F2021.04.22.21255637.atom) 5. 5.Tang YW, Schmitz JE, Persing DH, Stratton CW. Laboratory Diagnosis of COVID-19: Current Issues and Challenges. J Clin Microbiol 2020; 58(6). 6. 6.Xu Y, Xiao M, Liu X, et al. Significance of serology testing to assist timely diagnosis of SARS-CoV-2 infections: implication from a family cluster. Emerg Microbes Infect 2020; 9(1): 924–7. 7. 7.Hirotsu Y, Maejima M, Shibusawa M, et al. Comparison of automated SARS-CoV-2 antigen test for COVID-19 infection with quantitative RT-PCR using 313 nasopharyngeal swabs, including from seven serially followed patients. Int J Infect Dis 2020; 99: 397–402. [CrossRef](http://medrxiv.org/lookup/external-ref?access_num=10.1016/j.ijid.2020.08.029&link_type=DOI) [PubMed](http://medrxiv.org/lookup/external-ref?access_num=32800855&link_type=MED&atom=%2Fmedrxiv%2Fearly%2F2021%2F04%2F22%2F2021.04.22.21255637.atom) 8. 8.Lambert-Niclot S, Cuffel A, Le Pape S, et al. Evaluation of a Rapid Diagnostic Assay for Detection of SARS-CoV-2 Antigen in Nasopharyngeal Swabs. J Clin Microbiol 2020; 58(8). 9. 9.Dinnes J, Deeks JJ, Adriano A, et al. Rapid, point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection. Cochrane Database Syst Rev 2020; 8: CD013705. [PubMed](http://medrxiv.org/lookup/external-ref?access_num=32845525&link_type=MED&atom=%2Fmedrxiv%2Fearly%2F2021%2F04%2F22%2F2021.04.22.21255637.atom) 10. 10.Porte L, Legarraga P, Vollrath V, et al. Evaluation of a novel antigen-based rapid detection test for the diagnosis of SARS-CoV-2 in respiratory samples. Int J Infect Dis 2020; 99: 328–33. [CrossRef](http://medrxiv.org/lookup/external-ref?access_num=10.1016/j.ijid.2020.05.098&link_type=DOI) [PubMed](http://medrxiv.org/lookup/external-ref?access_num=32497809&link_type=MED&atom=%2Fmedrxiv%2Fearly%2F2021%2F04%2F22%2F2021.04.22.21255637.atom) 11. 11.Roche. [https://www.roche.de/res/content/11722/40338-2\_onepager\_sars-cov-2\_a4\_v2\_low\_ksc.pdf](https://www.roche.de/res/content/11722/40338-2\_onepager\_sars-cov-2\_a4_v2_low_ksc.pdf). 12. 12.Cerutti F, Burdino E, Milia MG, et al. Urgent need of rapid tests for SARS CoV-2 antigen detection: Evaluation of the SD-Biosensor antigen test for SARS-CoV-2. J Clin Virol 2020; 132: 104654. [CrossRef](http://medrxiv.org/lookup/external-ref?access_num=10.1016/j.jcv.2020.104654&link_type=DOI) [PubMed](http://medrxiv.org/lookup/external-ref?access_num=33053494&link_type=MED&atom=%2Fmedrxiv%2Fearly%2F2021%2F04%2F22%2F2021.04.22.21255637.atom) 13. 13.Linares M, Perez-Tanoira R, Carrero A, et al. Panbio antigen rapid test is reliable to diagnose SARS-CoV-2 infection in the first 7 days after the onset of symptoms. J Clin Virol 2020; 133: 104659. [CrossRef](http://medrxiv.org/lookup/external-ref?access_num=10.1016/j.jcv.2020.104659&link_type=DOI) 14. 14.Young S, Taylor SN, Cammarata CL, et al. Clinical Evaluation of BD Veritor SARS-CoV-2 Point-of-Care Test Performance Compared to PCR-Based Testing and versus the Sofia 2 SARS Antigen Point-of-Care Test. J Clin Microbiol 2020; 59(1). 15. 15.[https://www.idsociety.org/practice-guideline/covid-19-guideline-diagnostics/](https://www.idsociety.org/practice-guideline/covid-19-guideline-diagnostics/). Accessed 02.02.2021.