Abstract
Introduction Point-of-care ultrasound (POCUS) has the potential to transform healthcare delivery in the era of COVID-19 with its diagnostic and therapeutic expediency. It can be performed by clinicians already at the bedside, which permits an immediate and augmented assessment of a patient. Although lung ultrasound can be used to accurately diagnose a variety of disease states such as pneumothorax, pleural effusions, pneumonia and interstitial lung disease2, there are limited reports on the sonographic manifestations of COVID-19. There is an urgent need to identify alternative diagnostic modalities that can be immediately employed at the bedside of COVID-19 patients.
Methods This study was conducted at two medical centers in the United States from 3/21/2020-6/01/2020. Any adult who was hospitalized with COVID-19 (based on symptomatology and a confirmatory RT-PCR for SARS-CoV-2) and received a pulmonary POCUS examination was included. Providers were instructed to use a 12-zone scanning protocol for pulmonary views and save 6 second clips of each lung zone. This study utilized several POCUS devices, including Butterfly IQ, Vave, Lumify, and Sonosite. The collected images were interpreted by the study researchers based on a consensus document developed by the study authors and previously accepted definitions of lung POCUS findings.
Results A total of 22 eligible patients who received 36 lung scans were included in our study. Eleven (50%) patients experienced clinical deterioration (defined as either ICU admission, invasive mechanical ventilation, or death within 28 days from the initial symptom onset). Among the 36 lung scans collected, only 3 (8%) were classified as normal. The remaining scans had the following abnormalities: presence of B-lines (n=32, 89%), consolidations (n=20, 56%), pleural thickening (n=17, 47%), and pleural effusion (n=4, 11%). Out of 20 scans with consolidations, 14 (70%) were subpleural and 5 (25%) were translobar. A-lines were present in 26 (72%) of patients, although they were only observed in the majority of the collected lung zones in 5 (14%) of patients. Ultrasound findings were stratified by time from symptom onset to the scan based on the following time periods: early (0-6 days), middle (7-13 days), and late (14-28 days). B-lines appeared early after symptom onset and persisted well into the late disease course. In contrast, pleural thickening increased in frequency over time (early: 25%, middle: 47%, late: 67%). Subpleural consolidations also appeared in higher frequency later in the disease course (early: 13%, middle 42%, late: 56%).
Discussion certain lung ultrasound findings may be common in Covid-19, while others may appear later in the disease course or only occur in patients who experience clinical deterioration. Future efforts should investigate the predictive utility of consolidations, pleural thickening and B-lines for clinical deterioration and compare them to traditional radiological studies such as X-rays or CTs.
Competing Interest Statement
Andre Kumar, MD, MEd is a paid consultant for Vave Health, which manufactures one of the ultrasound devices used in this study. His consultant duties include providing feedback on product development. The other authors do not have any items to disclose.
Clinical Trial
NCT04384055
Funding Statement
This research was not funded by a private or governmental body.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Our institutional review boards approved this study.
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All summary data are available to individuals who request it. We cannot share data that contains PHI.