ABSTRACT
Aim In the diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), reverse transcriptase-polymerase chain reaction (RT-PCR) technique is often used. We evaluated the compatibility of SARS-CoV-2 RT-PCR kits containing different gene targets during the pandemic.
Materials & methods Samples were tested by Bio-Speddy® (RdRp gene) and Diagnovital® (RdRp+E genes). The correlation between two assays were determined by Deming regression and chi-square heatmap analyses.
Results Diagnovital PCR kit showed in a constricted range and conveniently exponential amplification curves than Bio-Speedy PCR kit. While the correlation increased when a secondary biomarker was added to the kit.
Conclusion In an unknown sample, using together different PCR kits that target different genes during the pandemic situation may provide a more accurate diagnosis of SARS-CoV-2.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
Figen Sarigul wrote the article Osman Doluca and Murat Sayan worked the samples by RT-PCR Sila Akhan collected the samples. There is no external funding.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This study was approved by the COVID-19 Scientific Research Committee of Ministry of Health (S.B. 2020-05-13T14_11_33) and by local Non-Interventional Research Ethics Committee of Kocaeli University (GOKAEK-2020/08.30 - 2020/144).
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Data were collected by Sila Akhan and Murat Sayan.