Abstract
Background RT-PCR test for identification of viral nucleic acid is the current standard diagnostic method for the diagnosis of COVID-19 disease but technical reasons limit the utilization of this assay onlarge scalescreenings.
Method We verified in a consecutive series of 191 symptomatic patients the clinical information that new rapid serological colorimetric test qualitatively analyzing IgM/IgG expression can provide with respect to standard assay and with respect to clinical outcome of patients.
Results Rapid serological test showed a sensitivity of 30% and a specificity of 89% with respect to the standard assay but, interestingly, these performances improve after 8 days of symptoms appearance. After 10 days of symptoms the predictive value of rapid serological test is higher than that of standardassay. When the behaviour of the two immunoglobulins was evaluated with respect to time length of symptoms appaerance, no significant difference in immunoglobulins behaviour was shown.
Conclusions The rapid serological test analyzed in the present study is candidate to provide information on immunoreaction of the subject to COVID-19 exposure.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
Partially funded by Ministry of Health-Italian Government, Ricerca Corrente 2020
Author Declarations
All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All relevant data are displayed in the manuscript.