ABSTRACT
Background Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody lateral flow immunoassays (LFIA) can be carried out in the home and have been used as an affordable and practical approach to large-scale antibody prevalence studies. However, assay performance differs from that of high-throughput laboratory-based assays which can be highly sensitive. We explore LFIA performance under field conditions compared to laboratory-based ELISA and assess the potential of LFIAs to identify people who lack functional antibodies following infection or vaccination.
Methods Field evaluation of a self-administered LFIA test (Fortress, NI) among 3758 participants from the REal-time Assessment of Community Transmission-2 (REACT-2) study in England selected based on vaccination history and previous LFIA result to ensure a range of antibody titres. In July 2021, participants performed, at home, a self-administered LFIA on finger-prick blood, reported and submitted a photograph of the result, and provided a self-collected capillary blood sample (Tasso-SST) for serological assessment of IgG antibodies to the spike protein using the Roche Elecsys® Anti-SARS-CoV-2 assay. We compared the self-administered and reported LFIA result to the quantitative Roche assay and checked the reading of the LFIA result with an automated image analysis (ALFA). In a subsample of 250 participants, we compared the results to live virus neutralisation.
Results Almost all participants (3593/3758, 95.6%) had been vaccinated or reported prior infection, with most having received one (862, 22.9%) or two (2430, 64.7%) COVID-19 vaccine doses. Overall, 2777/3758 (73.9%) were positive on self-reported LFIA, 2811/3457 (81.3%) positive by LFIA when ALFA-reported, and 3622/3758 (96.4%) positive on Roche anti-S (using the manufacturer reference standard threshold for positivity of 0.8 U ml-1). Live virus neutralisation was detected in 169 of 250 randomly selected samples (67.6%); 133/169 were positive with self-reported LFIA (sensitivity 78.7%; 95% CI 71.8, 84.6), 142/155 (91.6%; 86.1, 95.5) with ALFA, and 169 (100%; 97.8, 100.0) with Roche anti-S. There were 81 samples with no detectable virus neutralisation; 47/81 were negative with self-reported LFIA (specificity 58.0%; 95% CI 46.5, 68.9), 34/75 (45.3%; 33.8, 57.3) with ALFA, and 0/81 (0%; 0.0, 4.5) with Roche anti-S. All 250 samples remained positive with Roche anti-S when the threshold was increased to 1000U ml-1.
Conclusions Self-administered LFIA can provide insights into population patterns of infection and vaccine response, and sensitivity can be improved with automated reading of the result. The LFIA is less sensitive than a quantitative antibody test, but the positivity in LFIA correlates better than the quantitative ELISA with virus neutralisation.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
The work was supported by the Department of Health and Social Care in England.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
This work was undertaken as part of the REACT-2 study, with ethical approval from South Central Berkshire B Research Ethics Committee (REC ref: 20/SC/0206; IRAS 283805)
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data produced in the present study are available upon reasonable request to the authors