Abstract
The newly emerged Omicron variant of SARS-CoV-2 has numerous mutations that are not found in other variants of concern (VOCs). Despite acquiring extended functions in adapting to the host-cell environment, the viral genetic variation exerts a potential negative impact on a molecular test, which in turn, compromises public health and safety. The Liberty16 has been clinically validated as a flexible and accessible device system for running the affordable SalivaDirect™ real time PCR detection assay for SARS-CoV-2 especially in low resource settings. Preliminary, based on in-silico sequence analysis, we found that Omicron’s mutation at position 28,311 overlaps with the CDC 2019-nCoV_N1 probe binding region. In order to verify the performance of CDC 2019-nCoV-N1 primers-probe set in detecting the Omicron variant of SARS-CoV-2, plasmids containing Wuhan/WH01/2019 (wild-type) and B.1.1.529 (Omicron) sequences were serially diluted and subsequently directed for SalivaDirect™ RT-qPCR detection on Liberty16 using commercially procured reagents. Our findings provide analytical support for reports that the mutations in the Omicron variant have little or no impact on SalivaDirect™ assay in terms of amplification efficiency and detection sensitivity using either standard and the recently reported fast Liberty16 SalivaDirect™ thermal cycling protocols.
Competing Interest Statement
The authors are employees of, and received funding from, Ubiquitome Limited, the manufacturer of Liberty 16 described in the paper. The authors have no other relevant affiliations or financial involvement with any organization or entity with a financial interest in or financial conflict with the subject matter or materials discussed in the manuscript apart from those disclosed.
Funding Statement
We thank Dr Anne Wylie for her review of this manuscript and Anne and the SalivaDirect™ team for their continued support for SARS-CoV-2 accessible testing solutions for low resource settings.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data produced in the present study are available upon reasonable request to the authors