Abstract
Due to the ongoing pandemic, various types of facemasks such as N-95, surgical mask and cloth masks are being used as an essential protective measure. The filtration efficiency of these masks were tested before and after sterilization by different methods for two flow rates conditions corresponding to normal breathe rate (20 lpm) and during sneezing (90 lpm). Sterilization techniques used here are autoclaving (30 and 60 minutes), dry oven heating (30 and 60 minutes), gamma irradiation (15 and 25 kGy), hot water washing with and without detergent and immersing in 10% concentration of liquid hydrogen peroxide for 30 minutes. As expected, the N-95 is the greatest filtering efficiency among all the other type face masks. The best method to sterilize N-95 masks without affecting its performance is by using dry heat with temperature ranging from 70-80°C. The cloth masks and surgical mask are performed more or less same for both flow conditions. As an affordable sterilization method hot water washing is highly recommended which does not deteriorate the efficiency of the masks and can be used for the general public. The use of double or triple layer cotton cloth masks in the general public serves fit for the purpose than surgical masks. The surgical mask can be sterilized only few times with the help of dry heat, hot water wash and/or autoclave.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
There was no funding source for this study.
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
Yes