Abstract
Prolonged survival of SARS-CoV-2 on environmental surfaces and personal protective equipment (PPE) may lead to these surfaces transmitting disease to others. This article reports the effectiveness of a pulsed xenon ultraviolet (PX-UV) disinfection system in reducing the load of SARS-CoV-2 on hard surfaces and N95 respirators. Chamber slides and N95 respirator material were directly inoculated with SARS-CoV-2 and exposed to different durations of PX-UV disinfection. For hard surfaces, disinfection for 1, 2, and 5 minutes resulted in 3.53 Log10, >4.54 Log10, and >4.12 Log10 reductions in viral load, respectively. For N95 respirators, disinfection for 5 minutes resulted in >4.79 Log10 reduction in viral load. We found that PX-UV significantly reduces SARS-CoV-2 on hard surfaces and N95 respirators. With the potential to rapidly disinfectant environmental surfaces and N95 respirators, PX-UV devices are a promising technology for the reduction of environmental and PPE bioburden and to enhance both HCW and patient safety by reducing the risk of exposure to SARS-CoV-2.
Competing Interest Statement
Dr. Simmons reports personal fees from Xenex Disinfection Services, Inc., during the conduct of the study; personal fees from Xenex Disinfection Services, Inc., outside the submitted work. Dr. Carrion Jr. has nothing to disclose. Dr. Alfson reports grants from Xenex Disinfection Services, Inc., during the conduct of the study. Ms. Staples reports grants from Xenex Disinfection Services, Inc. during the conduct of the study. Dr. Jinadatha reports grants from Xenex Disinfection Services, Inc., outside the submitted work. Dr Jinadatha has served as principal investigator on other research projects conducted at Central Texas Veterans Health Care System, which were funded by Xenex Disinfection Services, Inc. and governed by the Cooperative Research and Development Agreement between the 2 entities. Dr. Jarvis has nothing to disclose. Dr. Sampathkumar has nothing to disclose. Dr. Chemaly reports grants and personal fees from Xenex, outside the submitted work. Dr. Khawaja has nothing to disclose. Dr. Povroznik reports personal fees from Xenex, outside the submitted work. Dr. Jackson has nothing to disclose. Dr. Kaye has nothing to disclose. Dr. Rodriguez has nothing to disclose. Dr. Stibich reports other from Xenex, outside the submitted work; and Employee and shareholder at Xenex.
Funding Statement
Funding for the laboratory testing was provided by Xenex Disinfection Services, Inc.
Author Declarations
All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Footnotes
Disclosures:
Dr. Simmons reports personal fees from Xenex Disinfection Services, Inc., during the conduct of the study; personal fees from Xenex Disinfection Services, Inc., outside the submitted work.
Dr. Carrion Jr. has nothing to disclose.
Dr. Alfson reports grants from Xenex Disinfection Services, Inc., during the conduct of the study.
Ms. Staples reports grants from Xenex Disinfection Services, Inc. during the conduct of the study.
Dr. Jinadatha reports grants from Xenex Disinfection Services, Inc., outside the submitted work. Dr Jinadatha has served as principal investigator on other research projects conducted at Central Texas Veterans Health Care System, which were funded by Xenex Disinfection Services, Inc. and governed by the Cooperative Research and Development Agreement between the 2 entities.
Dr. Jarvis has nothing to disclose.
Dr. Sampathkumar has nothing to disclose.
Dr. Chemaly reports grants and personal fees from Xenex, outside the submitted work.
Dr. Khawaja has nothing to disclose.
Dr. Povroznik reports personal fees from Xenex, outside the submitted work.
Dr. Jackson has nothing to disclose.
Dr. Kaye has nothing to disclose.
Dr. Rodriguez has nothing to disclose.
Dr. Stibich reports other from Xenex, outside the submitted work; and Employee and shareholder at Xenex.
Disclaimer: The views expressed in this commentary are those of the author and do not represent any position, policy, or opinion of the U.S. Department of Veterans Affairs (VA). This work is not endorsed by the VA, was not conducted on VA premises, and hence does not constitute VA research.
Data Availability
All data generated or analysed during this study are included in this published article