Impact of regadenoson-induced myocardial creep on dynamic rubidium-82 PET myocardial blood flow quantification

SS Koenders, JD Van Dijk, PL Jager… - Journal of Nuclear …, 2019 - Elsevier
Background Repositioning of the heart during myocardial perfusion imaging (MPI) using
Rubidium-82 (Rb-82) PET may occur when using regadenoson. Our aim was to determine the …

Machine learning based model to diagnose obstructive coronary artery disease using calcium scoring, PET imaging, and clinical data

JA van Dalen, SS Koenders, RJ Metselaar… - Journal of Nuclear …, 2023 - Elsevier
… Author links open overlay panel JA van Dalen PhD a , SS Koenders MSc b e , RJ Metselaar
MSc b e , BN Vendel MD b , DJ Slotman MSc c , M. Mouden MD, PhD d , CH Slump PhD e , …

Value of SiPM PET in myocardial perfusion imaging using Rubidium-82

SS Koenders, JA Van Dalen, PL Jager… - Journal of Nuclear …, 2022 - Elsevier
Background PET scanners using silicon photomultipliers with digital readout (SiPM PET)
have an improved temporal and spatial resolution compared to PET scanners using …

[HTML][HTML] Diagnostic value of regional myocardial flow reserve measurements using Rubidium-82 PET: Disclosures none

SS Koenders, JA van Dalen, PL Jager… - … International Journal of …, 2022 - Springer
Purpose Visual assessment of Rubidium (Rb-82) PET myocardial perfusion images is
usually combined with global myocardial flow reserve (MFR) measurements. However, small …

How to detect and correct myocardial creep in myocardial perfusion imaging using Rubidium-82 PET?

SS Koenders, JD Van Dijk, PL Jager… - Journal of Nuclear …, 2019 - Elsevier
Reliability of myocardial blood flow (MBF) quantification in myocardial perfusion imaging (MPI)
using PET can majorly be affected by the occurrence of myocardial creep when using …

Effect of temporal sampling protocols on myocardial blood flow measurements using rubidium-82 PET

SS Koenders, JD van Dijk, PL Jager, M Mouden… - Journal of Nuclear …, 2022 - Elsevier
… Author links open overlay panel SS Koenders MSc a d , JD van Dijk MSc, PhD a , PL Jager
MD, PhD a , M. Mouden MD, PhD c , AG Tegelaar BSc a , CH Slump PhD d , JA van Dalen …

Patient-tailored risk assessment of obstructive coronary artery disease using Rubidium-82 PET-based myocardial flow quantification with visual interpretation

SS Koenders, JA van Dalen, PL Jager… - Journal of Nuclear …, 2023 - Elsevier
Introduction Our aim was to estimate the probability of obstructive CAD (oCAD) for an individual
patient as a function of the myocardial flow reserve (MFR) measured with Rubidium-82 (…

Entropy-based myocardial blood flow measurements using PET: A way to improve reproducibility

J Van Dalen, SS Koenders, BN Vendel… - European Heart …, 2021 - academic.oup.com
Funding Acknowledgements Type of funding sources: None. Background and purpose
Myocardial blood flow (MBF) measurements using PET are increasingly used to guide the …

Value of regional myocardial flow measurements using Rubidium-82 PET

SS Koenders, JA Van Dalen, PL Jager… - European Heart …, 2021 - academic.oup.com
Funding Acknowledgements Type of funding sources: None. Introduction The combination
of myocardial blood flow (MBF) measurements using Rubidium-82 (Rb-82) PET and visual …

[HTML][HTML] The next step in improving (semi-) quantitative MPI PET

SS Koenders, JA van Dalen, JD van Dijk - Journal of Nuclear Cardiology, 2022 - Springer
Background Myocardial blood flow (MBF) quantification with PET results in an improved risk
assessment of coronary artery disease (CAD) in addition to semi-quantitative myocardial …