Michel M. MaharbizProfessor of Electrical Engineering and Computer Science, University of California, Berkeley Verified email at berkeley.edu Cited by 7596 |
A wireless millimetre-scale implantable neural stimulator with ultrasonically powered bidirectional communication
…, JE Kay, JM Carmena, MM Maharbiz… - Nature biomedical …, 2020 - nature.com
Clinically approved neural stimulators are limited by battery requirements, as well as by their
large size compared with the stimulation targets. Here, we describe a wireless, leadless …
large size compared with the stimulation targets. Here, we describe a wireless, leadless …
[PDF][PDF] Wireless recording in the peripheral nervous system with ultrasonic neural dust
The emerging field of bioelectronic medicine seeks methods for deciphering and modulating
electrophysiological activity in the body to attain therapeutic effects at target organs. Current …
electrophysiological activity in the body to attain therapeutic effects at target organs. Current …
A highly elastic, capacitive strain gauge based on percolating nanotube networks
We present a highly elastic strain gauge based on capacitive sensing of parallel, carbon
nanotube-based percolation electrodes separated by a dielectric elastomer. The fabrication, …
nanotube-based percolation electrodes separated by a dielectric elastomer. The fabrication, …
Neural dust: An ultrasonic, low power solution for chronic brain-machine interfaces
A major hurdle in brain-machine interfaces (BMI) is the lack of an implantable neural interface
system that remains viable for a lifetime. This paper explores the fundamental system …
system that remains viable for a lifetime. This paper explores the fundamental system …
[HTML][HTML] Monitoring deep-tissue oxygenation with a millimeter-scale ultrasonic implant
…, JR Fineman, E Maltepe, MM Maharbiz - Nature …, 2021 - nature.com
Vascular complications following solid organ transplantation may lead to graft ischemia,
dysfunction or loss. Imaging approaches can provide intermittent assessments of graft perfusion, …
dysfunction or loss. Imaging approaches can provide intermittent assessments of graft perfusion, …
A minimally invasive 64-channel wireless μECoG implant
<?Pub Dtl=""?> Emerging applications in brain–machine interface systems require high-resolution,
chronic multisite cortical recordings, which cannot be obtained with existing …
chronic multisite cortical recordings, which cannot be obtained with existing …
[HTML][HTML] Physical principles for scalable neural recording
Simultaneously measuring the activities of all neurons in a mammalian brain at millisecond
resolution is a challenge beyond the limits of existing techniques in neuroscience. Entirely …
resolution is a challenge beyond the limits of existing techniques in neuroscience. Entirely …
[HTML][HTML] Impedance sensing device enables early detection of pressure ulcers in vivo
When pressure is applied to a localized area of the body for an extended time, the resulting
loss of blood flow and subsequent reperfusion to the tissue causes cell death and a pressure …
loss of blood flow and subsequent reperfusion to the tissue causes cell death and a pressure …
Translational opportunities and challenges of invasive electrodes for neural interfaces
…, JL Edmunds, DK Piech, MM Maharbiz - Nature Biomedical …, 2023 - nature.com
Invasive brain–machine interfaces can restore motor, sensory and cognitive functions.
However, their clinical adoption has been hindered by the surgical risk of implantation and by …
However, their clinical adoption has been hindered by the surgical risk of implantation and by …
Model validation of untethered, ultrasonic neural dust motes for cortical recording
A major hurdle in brain–machine interfaces (BMI) is the lack of an implantable neural interface
system that remains viable for a substantial fraction of the user's lifetime. Recently, sub-…