Density‐weighted concentric circle trajectories for high resolution brain magnetic resonance spectroscopic imaging at 7T
Purpose Full‐slice magnetic resonance spectroscopic imaging at T is especially vulnerable
to lipid contaminations arising from regions close to the skull. This contamination can be …
to lipid contaminations arising from regions close to the skull. This contamination can be …
Clinical high-resolution 3D-MR spectroscopic imaging of the human brain at 7 T
Objectives Available clinical magnetic resonance spectroscopic imaging (MRSI) sequences
are hampered by long scan times, low spatial resolution, strong field inhomogeneities, …
are hampered by long scan times, low spatial resolution, strong field inhomogeneities, …
Non‐Cartesian GRAPPA and coil combination using interleaved calibration data–application to concentric‐ring MRSI of the human brain at 7T
Purpose Proton MR spectroscopic imaging (MRSI) benefits from B 0 ≥ 7T and multichannel
receive coils, promising substantial resolution improvements. However, MRSI acquisition …
receive coils, promising substantial resolution improvements. However, MRSI acquisition …
k‐Space‐based coil combination via geometric deep learning for reconstruction of non‐Cartesian MRSI data
S Motyka, L Hingerl, B Strasser… - Magnetic …, 2021 - Wiley Online Library
Purpose State‐of‐the‐art whole‐brain MRSI with spatial‐spectral encoding and multichannel
acquisition generates huge amounts of data, which must be efficiently processed to stay …
acquisition generates huge amounts of data, which must be efficiently processed to stay …
[HTML][HTML] Ultra-high resolution brain metabolite mapping at 7 T by short-TR Hadamard-encoded FID-MRSI
MRSI in the brain at ≥7 T is a technique of great promise, but has been limited mainly by low
B 0 /B 1 + -homogeneity, specific absorption rate restrictions, long measurement times, and …
B 0 /B 1 + -homogeneity, specific absorption rate restrictions, long measurement times, and …
Whole-slice mapping of GABA and GABA+ at 7T via adiabatic MEGA-editing, real-time instability correction, and concentric circle readout
An adiabatic MEscher-GArwood (MEGA)-editing scheme, using asymmetric hyperbolic secant
editing pulses, was developed and implemented in a B 1 + -insensitive, 1D-semiLASER (…
editing pulses, was developed and implemented in a B 1 + -insensitive, 1D-semiLASER (…
Extensive brain pathologic alterations detected with 7.0-T MR spectroscopic imaging associated with disability in multiple sclerosis
Background MR spectroscopic imaging (MRSI) allows in vivo assessment of brain metabolism
and is of special interest in multiple sclerosis (MS), where morphologic MRI cannot depict …
and is of special interest in multiple sclerosis (MS), where morphologic MRI cannot depict …
[HTML][HTML] High-resolution metabolic imaging of high-grade gliomas using 7T-CRT-FID-MRSI
Objectives Successful neurosurgical intervention in gliomas depends on the precision of the
preoperative definition of the tumor and its margins since a safe maximum resection …
preoperative definition of the tumor and its margins since a safe maximum resection …
[HTML][HTML] Noninvasive 3-dimensional 1H-magnetic resonance spectroscopic imaging of human brain glucose and neurotransmitter metabolism using deuterium …
Objectives Noninvasive, affordable, and reliable mapping of brain glucose metabolism is of
critical interest for clinical research and routine application as metabolic impairment is linked …
critical interest for clinical research and routine application as metabolic impairment is linked …
Inter‐subject stability and regional concentration estimates of 3D‐FID‐MRSI in the human brain at 7 T
…, P Lazen, C Cadrien, S Sharma, L Hingerl… - NMR in …, 2021 - Wiley Online Library
Purpose Recently, a 3D‐concentric ring trajectory (CRT)‐based free induction decay (FID)‐MRSI
sequence was introduced for fast high‐resolution metabolic imaging at 7 T. This …
sequence was introduced for fast high‐resolution metabolic imaging at 7 T. This …