A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology
K Erlandsson, I Buvat, PH Pretorius… - Physics in Medicine …, 2012 - iopscience.iop.org
Accurate quantification in PET and SPECT requires correction for a number of physical
factors, such as photon attenuation, Compton scattering and random coincidences (in PET). …
factors, such as photon attenuation, Compton scattering and random coincidences (in PET). …
PETPVC: a toolbox for performing partial volume correction techniques in positron emission tomography
…, K Thielemans, BF Hutton, K Erlandsson - Physics in Medicine …, 2016 - iopscience.iop.org
Positron emission tomography (PET) images are degraded by a phenomenon known as the
partial volume effect (PVE). Approaches have been developed to reduce PVEs, typically …
partial volume effect (PVE). Approaches have been developed to reduce PVEs, typically …
Fast accurate iterative reconstruction for low-statistics positron volume imaging
AJ Reader, K Erlandsson, MA Flower… - Physics in Medicine & …, 1998 - iopscience.iop.org
A fast accurate iterative reconstruction (FAIR) method suitable for low-statistics positron
volume imaging has been developed. The method, based on the expectation maximization-…
volume imaging has been developed. The method, based on the expectation maximization-…
Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology
K Erlandsson, K Kacperski… - Physics in Medicine …, 2009 - iopscience.iop.org
D-SPECT (Spectrum Dynamics, Israel) is a novel SPECT system for cardiac perfusion
studies. Based on CZT detectors, region-centric scanning, high-sensitivity collimators and …
studies. Based on CZT detectors, region-centric scanning, high-sensitivity collimators and …
The importance of appropriate partial volume correction for PET quantification in Alzheimer's disease
Purpose Alzheimer’s disease (AD) is the most common form of dementia. Clinically, it is
characterized by progressive cognitive and functional impairment with structural hallmarks of …
characterized by progressive cognitive and functional impairment with structural hallmarks of …
Quantification of myocardial perfusion reserve using dynamic SPECT imaging in humans: a feasibility study
…, A Haroon, P Slomka, K Erlandsson… - Journal of Nuclear …, 2013 - Soc Nuclear Med
Myocardial perfusion imaging (MPI) is well established in the diagnosis and workup of patients
with known or suspected coronary artery disease (CAD); however, it can underestimate …
with known or suspected coronary artery disease (CAD); however, it can underestimate …
Cortical Serotonin 5-HT 2A Receptor Binding and Social Communication in Adults With Asperger's Syndrome: An in Vivo SPECT Study
…, K Murphy, S Curran, K Erlandsson… - American Journal of …, 2006 - Am Psychiatric Assoc
Objective: The cause of autistic spectrum disorder (ie, autism and Asperger’s syndrome) is
unknown. The serotonergic (5-HT) system may be especially implicated. However, cortical 5-…
unknown. The serotonergic (5-HT) system may be especially implicated. However, cortical 5-…
[PDF][PDF] Pinhole SPECT: an approach to in vivo high resolution SPECT imaging in small laboratory animals
…, D Franceschi, SE Strand, K Erlandsson… - Journal of Nuclear …, 1994 - Soc Nuclear Med
MATERIALS AND METhODS Pinhole imaging was performed using a rotating scintillation
camera equipped with 1.0-, 2.0-and 3.3-mm aperture pinhole inserts in a low-energy pinhole …
camera equipped with 1.0-, 2.0-and 3.3-mm aperture pinhole inserts in a low-energy pinhole …
Relationship between ketamine-induced psychotic symptoms and NMDA receptor occupancy—a [123I]CNS-1261 SPET study
Rationale Ketamine induces effects resembling both positive and negative psychotic
symptoms of schizophrenia. These are thought to arise through its action as an uncompetitive …
symptoms of schizophrenia. These are thought to arise through its action as an uncompetitive …
Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera
…, D Van Gramberg, BF Hutton, K Erlandsson… - European journal of …, 2010 - Springer
Purpose We compared simultaneous dual-radionuclide (DR) stress and rest myocardial
perfusion imaging (MPI) with a novel solid-state cardiac camera and a conventional SPECT …
perfusion imaging (MPI) with a novel solid-state cardiac camera and a conventional SPECT …