A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology

K Erlandsson, I Buvat, PH Pretorius… - Physics in Medicine …, 2012 - iopscience.iop.org
Accurate quantification in PET and SPECT requires correction for a number of physical
factors, such as photon attenuation, Compton scattering and random coincidences (in PET). …

PETPVC: a toolbox for performing partial volume correction techniques in positron emission tomography

…, K Thielemans, BF Hutton, K Erlandsson - Physics in Medicine …, 2016 - iopscience.iop.org
Positron emission tomography (PET) images are degraded by a phenomenon known as the
partial volume effect (PVE). Approaches have been developed to reduce PVEs, typically …

Fast accurate iterative reconstruction for low-statistics positron volume imaging

AJ Reader, K Erlandsson, MA Flower… - Physics in Medicine & …, 1998 - iopscience.iop.org
A fast accurate iterative reconstruction (FAIR) method suitable for low-statistics positron
volume imaging has been developed. The method, based on the expectation maximization-…

Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology

K Erlandsson, K Kacperski… - Physics in Medicine …, 2009 - iopscience.iop.org
D-SPECT (Spectrum Dynamics, Israel) is a novel SPECT system for cardiac perfusion
studies. Based on CZT detectors, region-centric scanning, high-sensitivity collimators and …

The importance of appropriate partial volume correction for PET quantification in Alzheimer's disease

BA Thomas, K Erlandsson, M Modat, L Thurfjell… - European journal of …, 2011 - Springer
Purpose Alzheimer’s disease (AD) is the most common form of dementia. Clinically, it is
characterized by progressive cognitive and functional impairment with structural hallmarks of …

Quantification of myocardial perfusion reserve using dynamic SPECT imaging in humans: a feasibility study

…, A Haroon, P Slomka, K Erlandsson… - Journal of Nuclear …, 2013 - Soc Nuclear Med
Myocardial perfusion imaging (MPI) is well established in the diagnosis and workup of patients
with known or suspected coronary artery disease (CAD); however, it can underestimate …

Cortical Serotonin 5-HT 2A Receptor Binding and Social Communication in Adults With Asperger's Syndrome: An in Vivo SPECT Study

…, K Murphy, S Curran, K Erlandsson… - American Journal of …, 2006 - Am Psychiatric Assoc
Objective: The cause of autistic spectrum disorder (ie, autism and Asperger’s syndrome) is
unknown. The serotonergic (5-HT) system may be especially implicated. However, cortical 5-…

[PDF][PDF] Pinhole SPECT: an approach to in vivo high resolution SPECT imaging in small laboratory animals

…, D Franceschi, SE Strand, K Erlandsson… - Journal of Nuclear …, 1994 - Soc Nuclear Med
MATERIALS AND METhODS Pinhole imaging was performed using a rotating scintillation
camera equipped with 1.0-, 2.0-and 3.3-mm aperture pinhole inserts in a low-energy pinhole …

Relationship between ketamine-induced psychotic symptoms and NMDA receptor occupancy—a [123I]CNS-1261 SPET study

JM Stone, K Erlandsson, E Arstad, L Squassante… - …, 2008 - Springer
Rationale Ketamine induces effects resembling both positive and negative psychotic
symptoms of schizophrenia. These are thought to arise through its action as an uncompetitive …

Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera

…, D Van Gramberg, BF Hutton, K Erlandsson… - European journal of …, 2010 - Springer
Purpose We compared simultaneous dual-radionuclide (DR) stress and rest myocardial
perfusion imaging (MPI) with a novel solid-state cardiac camera and a conventional SPECT …