Precise quantification of pressure flow waveforms of a pulsatile ventricular assist device

A Ündar, CM Zapanta, JD Reibson, M Souba… - ASAIO …, 2005 - journals.lww.com
Unreliable quantification of flow pulsatility has hampered many efforts to assess the importance
of pulsatile perfusion. Generation of pulsatile flow depends upon an energy gradient. It is …

Quantification of perfusion modes in terms of surplus hemodynamic energy levels in a simulated pediatric CPB model

A Ündar, B Ji, B Lukic, CM Zapanta… - ASAIO …, 2006 - journals.lww.com
Quantification of Perfusion Modes in Terms of Surplus Hemody... : ASAIO Journal Quantification
of Perfusion Modes in Terms of Surplus Hemodynamic Energy Levels in a Simulated Pediatric …

Microtextured materials for circulatory support devices: preliminary studies

CM Zapanta, JW Griffith, GD Hess, BJ Doxtater… - Asaio …, 2006 - journals.lww.com
Thromboembolic events (TE) associated with circulatory support devices are a major source
of mortality and morbidity. Clinically, the lowest TE rates are claimed with devices that …

In vivo observation of cavitation on prosthetic heart valves

CM Zapanta, DR Stinebring, DS Sneckenberger… - ASAIO …, 1996 - journals.lww.com
In this study, a method to determine the existence of prosthetic heart valve cavitation in vivo
is presented. Pennsylvania State University Left Ventricular Assist Devices (LVADs) were …

[PDF][PDF] A comparison of the cavitation potential of prosthetic heart valves based on valve closing dynamics

CM Zapañta, DR Stinebring, S Deutsch… - Journal of Heart …, 1998 - researchgate.net
Background and aims of the study: This study compares the cavitation potential of prosthetic
heart valves based on valve closing dynamics. Methods: A laser sweeping technique …

Performance characterization of a rotary centrifugal left ventricular assist device with magnetic suspension

…, WJ Weiss, B Lukic, WE Pae, CM Zapanta… - Artificial …, 2008 - Wiley Online Library
The MiTiHeart (MiTiHeart Corporation, Gaithersburg, MD, USA) left ventricular assist device
(LVAD), a third‐generation blood pump, is being developed for destination therapy for adult …

A Method for Real-Time In Vitro Observation of Cavitation on Prosthetic Heart Valves

CM Zapanta, EG Liszka Jr, TC Lamson… - 1994 - asmedigitalcollection.asme.org
A method for real-time in vitro observation of cavitation on a prosthetic heart valve has been
developed. Cavitation of four blood analog fluids (distilled water, aqueous glycerin, aqueous …

Durability testing of a completely implantable electric total artificial heart

CM Zapanta, AJ Snyder, WJ Weiss, TJ Cleary… - ASAIO …, 2005 - journals.lww.com
In vitro durability testing was conducted on the Penn State/3M electric total artificial heart (ETAH)
to determine device durability and to evaluate device failures. A specialized mock …

Effect of the diastolic and systolic duration on valve cavitation in a pediatric pulsatile ventricular assist device

B Lukic, CM Zapanta, KA Griffith, WJ Weiss - ASAIO journal, 2005 - journals.lww.com
Minimization of cavitation is of high importance in the design of pulsatile ventricular assist
devices because cavitation can cause blood and valve surface damage. Cavitation is …

Multiscale analysis of surface thrombosis in vivo in a left ventricular assist system

…, G Rosenberg, WJ Weiss, AJ Snyder, CM Zapanta… - ASAIO …, 2005 - journals.lww.com
Thrombosis limits the success of ventricular assist devices as the demand for alternatives to
heart transplants is increasing. This study mapped the occurrence of thrombosis in a left …