Age significantly influences the sensitivity of SARS-CoV-2 rapid antibody assays

Int J Infect Dis. 2021 Aug:109:304-309. doi: 10.1016/j.ijid.2021.07.027. Epub 2021 Jul 13.

Abstract

Background: Point-of-care serological assays are a promising tool in COVID-19 diagnostics but do have limitations. Our study evaluated the sensitivity of five rapid antibody assays and explored factors influencing their sensitivity in detecting SARS-CoV-2-specific IgG and IgM antibodies.

Methods: Finger-prick blood samples from 102 participants, within 2-6 weeks of PCR-confirmed COVID-19 diagnosis, were tested for IgG and IgM using five rapid serological assays. The assay sensitivities were compared, and patient factors evaluated in order to investigate potential associations with assay sensitivity.

Results: Sensitivity ranged from 36% to 69% for IgG and 13% to 67% for IgM. Age was the only factor significantly influencing the likelihood of a detectable IgG or IgM response. Individuals aged 40 years and older had an increased likelihood of a detectable IgG or IgM antibody response by rapid antibody assay.

Conclusion: Rapid serological assays demonstrate significant variability when used in a real-world clinical context. There may be limitations in their use for COVID-19 diagnosis among the young.

Keywords: COVID-19; South Africa; age; antibody; diagnostics.

MeSH terms

  • Adult
  • Antibodies, Viral
  • COVID-19 Testing
  • COVID-19*
  • Humans
  • Immunoglobulin M
  • Middle Aged
  • SARS-CoV-2*
  • Sensitivity and Specificity

Substances

  • Antibodies, Viral
  • Immunoglobulin M