Multiple inert gas elimination technique by micropore membrane inlet mass spectrometry--a comparison with reference gas chromatography

J Appl Physiol (1985). 2013 Oct 15;115(8):1107-18. doi: 10.1152/japplphysiol.00072.2013. Epub 2013 Jul 18.

Abstract

The mismatching of alveolar ventilation and perfusion (VA/Q) is the major determinant of impaired gas exchange. The gold standard for measuring VA/Q distributions is based on measurements of the elimination and retention of infused inert gases. Conventional multiple inert gas elimination technique (MIGET) uses gas chromatography (GC) to measure the inert gas partial pressures, which requires tonometry of blood samples with a gas that can then be injected into the chromatograph. The method is laborious and requires meticulous care. A new technique based on micropore membrane inlet mass spectrometry (MMIMS) facilitates the handling of blood and gas samples and provides nearly real-time analysis. In this study we compared MIGET by GC and MMIMS in 10 piglets: 1) 3 with healthy lungs; 2) 4 with oleic acid injury; and 3) 3 with isolated left lower lobe ventilation. The different protocols ensured a large range of normal and abnormal VA/Q distributions. Eight inert gases (SF6, krypton, ethane, cyclopropane, desflurane, enflurane, diethyl ether, and acetone) were infused; six of these gases were measured with MMIMS, and six were measured with GC. We found close agreement of retention and excretion of the gases and the constructed VA/Q distributions between GC and MMIMS, and predicted PaO2 from both methods compared well with measured PaO2. VA/Q by GC produced more widely dispersed modes than MMIMS, explained in part by differences in the algorithms used to calculate VA/Q distributions. In conclusion, MMIMS enables faster measurement of VA/Q, is less demanding than GC, and produces comparable results.

Keywords: MIGET; gas chromatography; inert gases; mass spectrometry; membrane inlet; ventilation/perfusion distributions.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Animals, Newborn
  • Calibration
  • Chromatography, Gas* / standards
  • Disease Models, Animal
  • Equipment Design
  • Gas Chromatography-Mass Spectrometry* / instrumentation
  • Gas Chromatography-Mass Spectrometry* / methods
  • Gas Chromatography-Mass Spectrometry* / standards
  • Hyperventilation / blood
  • Hyperventilation / etiology
  • Hyperventilation / physiopathology
  • Lung Injury / blood
  • Lung Injury / chemically induced
  • Lung Injury / physiopathology
  • Manometry
  • Membranes, Artificial*
  • Micropore Filters*
  • Noble Gases / blood*
  • Oleic Acid
  • Partial Pressure
  • Porosity
  • Pulmonary Circulation
  • Pulmonary Gas Exchange
  • Pulmonary Ventilation*
  • Reference Standards
  • Respiration, Artificial
  • Swine
  • Time Factors
  • Ventilation-Perfusion Ratio*

Substances

  • Membranes, Artificial
  • Noble Gases
  • Oleic Acid