Skip to main content

Advertisement

Log in

Assessing the effects of sliding doors on an operating theatre climate

  • Research Article
  • Indoor/Outdoor Airflow and Air Quality
  • Published:
Building Simulation Aims and scope Submit manuscript

Abstract

Surgical site infections (SSIs) are the second to third most common site of health care associated infections (HAIs). It is very important to maintain good indoor air quality (IAQ) and the best ventilation system in the operating theatre (OT) to ensure health and safety for the patient and surgical team, also to reduce the risk of post-operative wound infection. Then a significant consideration in OTs is the control of aerosols, anesthesia gases and smoke. The present paper uses the airflow modeling based on computational fluid dynamics (CFD) to study the indoor climate of a standard ISO5 class OT with an ultraclean air filter system and a total ceiling unidirectional diffuser. The OT has a heating, ventilation, and air conditioning (HVAC) plant with a laminar airflow (LAF) or ultraclean ventilation. A simple method to analyze the effects of different sliding door conditions combined with crossing persons and persons with a stretcher crossing, on the OT climate, airflow patterns and the indoor pressures scheme, is provided. The proposed simulation method, that belongs to the indirect approach for a numerical simulation of solid object movements in a fluid, provides important knowledge on complex flow phenomena combined with multi-physical conditions. Results obtained by transient simulation show disruptions of the airflow inside the OT and different airflow displacement and distribution caused by surgery staff movements and sliding door opening and closing, but in particular static pressure changes in the HVAC plant system with important effects on ventilation system working conditions and its energy performances.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Brohus H, Balling KD, Jeppesen D (2006). Influence of movements on contaminant transport in an operating room. Indoor Air, 16: 356–372.

    Article  Google Scholar 

  • Chow TT, Kwan A, Lin Z, Bai W (2006a). A computer evaluation of ventilation performance in a negative-pressure operating theater. Anesthesia & Analgesia, 103: 913–918.

    Article  Google Scholar 

  • Chow TT, Kwan A, Lin Z, Bai W (2006b). Conversion of operating theatre from positive to negative pressure environment. Journal of Hospital Infection, 64: 371–378.

    Article  Google Scholar 

  • Chow TT, Yang XY (2005). Ventilation performance in the operating theatre against airborne infection: numerical study on an ultra-clean system. Journal of Hospital Infection, 59: 138–147.

    Article  Google Scholar 

  • Chow TT, Yang XY (2004). Ventilation performance in operating theatres against airborne infection: review of research activities and practical guidance. Journal of Hospital Infection, 56: 85–92.

    Article  Google Scholar 

  • Deuflhard P (1974). A modified Newton method for the solution of ill-conditioned systems of nonlinear equations with application to multiple shooting. Numerical Mathematics, 22: 289–315.

    Article  MathSciNet  Google Scholar 

  • Dharan S, Pittet D (2002). Environmental controls in operating theatres. Journal of Hospital Infection, 51: 79–84.

    Article  Google Scholar 

  • Dong S, Tu G, Cao R, Yu Z (2009). Numerical Study on Effects of Door-Opening on Airflow Patterns and Dynamic Cross-Contamination in an ISO Class 5 Operating Room. Transactions of Tianjin University, 15: 210–215.

    Article  Google Scholar 

  • Farnsworth JE, Goyal SM, Kim SW, Kuehn TH, Raynor PC, Ramakrishnan MA, Anantharaman S, Tang W (2006). Development of a method for bacteria and virus recovery from heating, ventilation, and air conditioning (HVAC) filters. Journal of Environmental Monitoring, 8: 1006–1013.

    Article  Google Scholar 

  • Hindmarsh H, Brown AC, Grant PN, Lee KE, Serban SL, Shumaker R, Woodward DE, Woodward CS (2005). SUNDIALS: Suite of nonlinear and differential/algebraic equation solvers. ACM Transactions on Mathematical Software, 31: 363–396.

    Article  MathSciNet  Google Scholar 

  • Halvonovà B, Melikov AK (2010). Performance of “ductless” personalized ventilation in conjunction with displacement ventilation: Impact of disturbances due to walking person(s). Building and Environment, 45: 427–436.

    Article  Google Scholar 

  • Ignat L, Pelletier D, Ilinca F (2000). A universal formulation of two-equation models for adaptive computation of turbulent flows. Computer Methods in Applied Mechanics and Engineering, 189: 1119–1139.

    Article  Google Scholar 

  • Launder BE, Spalding DB (1974). The Numerical Computation of Turbulent Flows. Computer Methods in Applied Mechanics and Engineering. Computer Methods in Applied Mechanics and Engineering, 3: 269–289.

    Article  Google Scholar 

  • Lin Y, Zmeureanu R (2008). Three-dimensional thermal and airflow (3D-TAF) model of a dome-covered house in Canada. Renewable Energy, 33: 22–34.

    Article  Google Scholar 

  • Liu J, Wang H, Wen W (2009). Numerical simulation on a horizontal airflow for airborne particles control in hospital operating room. Building and Environment, 44: 2284–2289.

    Article  Google Scholar 

  • Matzumoto H, Ohba Y (2004). The influence of a moving object on air distribution in displacement ventilated rooms. Journal of Asian Architecture and Building Engineering, 3: 71–75.

    Article  Google Scholar 

  • Melhado MA, Hensen JLM, Loomans M, Forejt L (2006). Review of operating room ventilation standards. In: Proceedings of the 17th International Air Conditioning and Ventilation Conference (STP, Society of Environmental Engineering 2006), Prague, Czech Republic.

  • Menazadeh F, Manning AP (2002). Comparison of operating room ventilation systems in the protection of surgical site. ASHRAE Transactions, 108(2): 3–15.

    Google Scholar 

  • Rygielski L, Uden D (2007). Creating comfort: Nine considerations for selecting the right hospital HVAC system. Health Facilities Management, 20: 19–23.

    Google Scholar 

  • Shih YC, Chiu CC, Wang O (2007). Dynamic airflow simulation within an isolation room. Building and Environment, 42: 3194–3209.

    Article  Google Scholar 

  • Talon D, Schoenleber T, Bertrand X, Vichard P (2006). Performances of different types of airflow system in operating theatre. Annales de Chirurgie, 131: 316–321.

    Article  Google Scholar 

  • Tang J, Li Y, Eames I, Chan P, Ridgway G (2006). Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises. Journal of Hospital Infection, 64: 100–114.

    Article  Google Scholar 

  • Tunga YC, Hu SC, Tsai TI, Chang IL (2009). An experimental study on ventilation efficiency of isolation room. Building and Environment, 44: 271–279.

    Article  Google Scholar 

  • van Schijndel AWM (2009). Integrated modelling of dynamic heat, air and moisture processes in buildings and systems using Simulink and COMSOL. Building Simulation, 2: 143–155.

    Article  Google Scholar 

  • Wilcox DC (1998), Turbulence Modelling for CFD, DCW Industries Inc.

  • Zhang ZL, Wachenfeldt BJ (2009). Numerical study on the heat storing capacity of concrete walls with air cavities. Energy and Buildings, 41: 769–773.

    Article  Google Scholar 

  • Zhao B, Yang C, Chen C, Feng C, Yang X, Sun L, Gong W, Yu L (2009). How many airborne particles emitted from a nurse will reach the breathing zone/body surface of the patient in ISO Class-5 singlebed hospital protective environments? A numerical analysis. Aerosol Science and Technology, 43: 990–1005.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Giuseppe Petrone.

Electronic supplementary material

Rights and permissions

Reprints and permissions

About this article

Cite this article

Balocco, C., Petrone, G. & Cammarata, G. Assessing the effects of sliding doors on an operating theatre climate. Build. Simul. 5, 73–83 (2012). https://doi.org/10.1007/s12273-012-0071-x

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-012-0071-x

Keywords

Navigation