PT - JOURNAL ARTICLE AU - Jeremy A. Garson AU - Samuel Badru AU - Anjna Badhan AU - Simon Dustan AU - Richard S. Tedder TI - Development of highly specific singleplex and multiplex real-time reverse transcription PCR assays for the identification of SARS-CoV-2 Omicron BA.1, BA.2 and Delta variants AID - 10.1101/2022.04.07.22273168 DP - 2022 Jan 01 TA - medRxiv PG - 2022.04.07.22273168 4099 - http://medrxiv.org/content/early/2022/04/14/2022.04.07.22273168.short 4100 - http://medrxiv.org/content/early/2022/04/14/2022.04.07.22273168.full AB - The Omicron variant of SARS-CoV-2 (B.1.1.529), first identified during November 2021, is rapidly spreading throughout the world, replacing the previously dominant Delta variant. Omicron has a high number of mutations in the spike gene, some of which are associated with greatly increased transmissibility and immune evasion. The BA.1 sublineage has been most prevalent but there is recent evidence that the BA.2 sublineage is increasing in proportion in many countries. Genome sequencing is the gold standard for Omicron identification but is relatively slow, resource intensive, of limited capacity and often unavailable. We therefore developed a simple, rapid reverse transcription PCR (RT-PCR) method for sensitive and specific detection of the Omicron variant, including both the BA.1 and BA.2 sublineages. The assay targets a total of 5 nucleotide mutations in the receptor binding domain of the spike gene that give rise to 4 amino acid substitutions at G339D, S371L, S373P and S375F. The forward primer was designed as a double-mismatch allele specific primer (DMAS) with an additional artificial mismatch located four nucleotides from the 3’ end to enhance binding specificity. Assay specificity was confirmed by testing a wide range of previously-sequenced culture-derived viral isolates and clinical samples including the Alpha, Beta and Delta variants and ‘wild type’ SARS-CoV-2. Respiratory syncytial virus and influenza A were also tested. The assay can be run in singleplex format, or alternatively as a multiplex RT-PCR to enable Omicron and Delta variants to be detected and distinguished within the same reaction by means of probes labelled with different fluorescent dyes. Sublineages BA.1 and BA.2 can be differentiated if required. The methods presented here can readily be established in any PCR laboratory and should provide valuable support for epidemiologic surveillance of Omicron infections, particularly in those regions that lack extensive sequencing facilities.Competing Interest StatementThe authors have declared no competing interest.Funding StatementNo external funding was receivedAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:North West - Greater Manchester East Research Ethics Committee, REC reference 20/NW/0231; IRAS ID 282820 gave ethical approval for this workI confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data produced in the present work are contained in the manuscript