RT Journal Article SR Electronic T1 Serum SARS-CoV-2 Antigens for the Determination of COVID-19 Severity JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2021.11.18.21266478 DO 10.1101/2021.11.18.21266478 A1 Julien Favresse A1 Jean-Louis Bayart A1 Clara David A1 Constant Gillot A1 Grégoire Wieërs A1 Gatien Roussel A1 Guillaume Sondag A1 Marc Elsen A1 Christine Eucher A1 Jean-Michel Dogné A1 Jonathan Douxfils YR 2021 UL http://medrxiv.org/content/early/2021/11/21/2021.11.18.21266478.abstract AB The diagnostic of SARS-CoV-2 infection relies on reverse transcriptase polymerase chain reactions (RT-PCR) performed on nasopharyngeal (NP) swabs. Nevertheless, false negative results can be obtained with inadequate sampling procedures making the use of other matrices of interest. This study aims at evaluating the kinetic of serum N antigen in severe and non-severe patients and compare the clinical performance of serum antigenic assays with NP RT-PCR. Ninety patients were included and monitored for several days. Disease severity was determined according to the WHO clinical progression scale. The serum N antigen was measured with a chemiluminescent assay (CLIA) and the Single Molecular Array (Simoa). Thresholds for severity were determined. In severe patients, the peak antigen response was observed 7 days after the onset of symptoms followed by a decline. No peak response was observed in non-severe patients. Severity threshold for the Simoa and the CLIA provided positive likelihood ratio of 30.0 and 10.9 for the timeframe between day 2 and day 14, respectively. Compared to NP RT-PCR, antigenic assays were able to discriminate the severity of the disease (p = 0.0174, 0.0310 and p = 0.1551 with the Simoa, the CLIA and the NP RT-PCR, respectively). Sensitive N antigen detection in serum thus provides a valuable new marker for COVID-19 diagnosis and evaluation of disease severity. When assessed during the first 2 weeks since the onset of symptoms, it may help in identifying patients at risk of developing severe COVID-19 to optimize better intensive care utilization.Competing Interest StatementYHLO provided the kits for the iFlash antigen assays and JDO received honorarium from YHLO outside the submitted work.Funding StatementThis study was funded by the University of NamurAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Medical Ethical Committee of Saint-Luc Bouge (Bouge, Belgium, approval number B0392020000005)I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesAll data produced in the present study are available upon reasonable request to the corresponding author